Safety Precautions; Insulation Resistance Test - Kenmore 79053 Service Manual

Table of Contents

Advertisement

REMOTE
CONTROL
Precaution: The Remote Controller will not operate properly if strong light strikes the sensor window of the air
conditioner or if there are obstacles between the Remote Controller and the air conditioner,
AUTO SWING
• Presstheairflowdirection control b utton forthe verticalIouver's to swingautomatically,
ON/OFF TIMER
- STOPPINGOPERATION
• Ever/timeyoupush thisbutton,whenthe set isoperating, t imeris set as follows.
(1 Hour_2Hours _ 3Hours - 4Hours-5Hcers _ 6Hours --_7Hours- 8Hours-9Hours - *
10Hours-11Hours- 12Hours - Cancel)
The SettingTemperature willbe raisedby 2°F 30rain.laterand by2°F after
another30 min.
- STARTINGOPERATION
• Everytime youpushthis button, w henthe set isnotoperating, t imer isset
as follow. (1Hour-2Hours - 3Hours- 4Hours-5Hours-6Hours-_7Hours
8Hours - , 9Hours _ 10Hours _ 11 Hours-- 1 2Hours -- Cancel)
ENERGY SAVER
The fanstopswhenthe compressor stopscooling,
• Approximately e very3 minutesthe fanwillturnon and checkthe room
air to determine if cooling is needed.
COOL/FAN
• Everytime youpushthis button, i t willtogglebetween COOLand FAN.
POWER
• To turnthe Set ON, pushthe button.To tumthe Set OFF, pushthe button again.
Thisbutton takespriority overanyotherbuttons.
Whenyoufirstturniton, the Set is onthe Highcoolmodeandthe temp.at 72°F
TEMPERATURE SEI"rlNG
• This button can automatically c ontrol t he temperature ofthe room.
The temperature can be set within a rangeof 60°Fto 86°F by I°F.
Selectthe lowernumber for lowertemperature ofthe room.
FAN SPEED
• Everytime youpushthisbutton it is setas follows. ( High---Low--- High..,)
POWER
FAN
SPEED
1.4 SAFETY PRECAUTIONS
1. When servicing, set the ROTARY SWITCH to
Off ( O ) and unplug the power cord.
2. Observe the original lead dress.
If a short circuit is found, replace all parts which
have been overheated or damaged by the short
circuit.
3. After servicing, make an insulation resistance test
to prevent the customer from being exposed to
shock hazards.
1.5 INSULATION
RESISTANCE
TEST
1. Unplug the power cord and connect a jumper
between 2 pins (black and white).
2. The grounding conductor (green or green and yel-
low) is to be open.
3. Measure the resistance value with an ohm meter
between the jumpered lead and each exposed
metallic part on the equipment at all position
[except Off ( 0 )] of the ROTARY SWITCH.
4. The value should be over 1 M_.