Show Interconnect Powerdelay; Show Interconnect Status - HP BL480c - ProLiant - 4 GB RAM User Manual

Onboard administrator command line interface user guide
Hide thumbs Also See for BL480c - ProLiant - 4 GB RAM:
Table of Contents

Advertisement

3. <absent>
4. <absent>

SHOW INTERCONNECT POWERDELAY

Command:
SHOW INTERCONNECT POWERDELAY {ALL | <bay number> [{ - | , } <bay
number>]}
Description:
Displays the PowerDelay status for the specified interconnects or range of interconnects
Access level/Bay level:
All
Bay specific
Restrictions:
None
Example
OA-0018FE27577F> SHOW INTERCONNECT POWERDELAY ALL
Current PowerDelay Status: Not in Progress
Bay
Device
---
--------------------------------
1
Cisco Catalyst Blade Switch 3120
2
Absent
3
Absent
4
Absent

SHOW INTERCONNECT STATUS

Command:
SHOW INTERCONNECT STATUS {ALL | <bay number> | <bay number>-<bay
number>}
Description:
Displays interconnect status information; UID state and health state
Access level/Bay level:
All
Bay specific
Restrictions:
You must have explicit access to a bay given by the ASSIGN INTERCONNECT command.
Example
OA-0018FE27577F> SHOW INTERCONNECT STATUS ALL
Interconnect Module #1 Status:
Status : OK
Thermal: OK
CPU Fault: OK
Health LED: OK
UID: Off
PowerDelay State
Delay (seconds)
------------
Disabled
Disabled
Disabled
Disabled