ters to be replaced and xx
through zz
and zz
1
E5 Terminates character replacement. Syntax = E5.
FE Compare character in current cursor position to the character "xx." If char-
acters are equal, increment cursor. If characters are not equal, no format
match. Syntax = FExx (xx stands for the hex value for an ASCII code, see
Code Page Mapping of Printed Barcodes
EC Check to make sure there is an ASCII number at the current cursor posi-
tion. If character is not numeric, format is aborted. Syntax = EC .
ED Check to make sure there is a non-numeric ASCII character at the current
cursor position. If character is numeric, format is aborted. Syntax = ED .
6 - 4
defines replacement characters, continuing
2
.
2
on page A-7.)