Note
Be sure to have an alphanu-
meric (programming) touch-
pad on hand for on-site
programming in installations
that do not include one as
part of the final system con-
figuration. This programming
touchpad can be connected
to the Programming Touch-
pad Header (see Figure 15)
using a Programming
Touchpad Cable (part no.
60-791).
Note
The panel cannot be used
on a digital or PBX phone
line. These systems are
designed only for digital type
devices that operate any-
where from 5 volts DC and
up. The panel uses an ana-
log modem and does not
have a digital converter,
adapter, or interface to oper-
ate with such systems.
Installing the System

Connecting Touchpads

SuperBus 2000 2x16 LCD Alphanumeric Touchpad (60-746-01)
SuperBus 2000 2x20 LCD Alphanumeric Touchpads (60-803, 60-809)
SuperBus 2000 2x20 VFD Alphanumeric Touchpad (60-804, 60-810)
SuperBus 2000 Fixed Display LCD Touchpad (60-820)
Alphanumeric touchpads can be used for installer programming, system operation, and user pro-
gramming. Fixed display touchpads can be used for system operation and user programming but
not for installer programming.
Connect 2x16 and fixed display LCD touchpads to the panel power output and bus terminals as
shown in Figure 15.
The 2x20 LCD/VFD touchpads include a supervised hardwire input for connection to a hardwire
detection device (see Figure 15 for an example of a normally closed connection).
Connect 2x20 LCD/VFD touchpads to the panel power output and bus terminals as shown in
Figure 15.
SuperBus 2000
2x16 LCD Alphanumeric
or
SuperBus 2000
Fixed English
LCD Touchpad
Figure 15. Connecting 2x16 Alphanumeric, Fixed Display LCD Touchpads and 2x20

Installing an RJ-31X Phone Jack (13-081)

Use the following guidelines when installing an RJ-31X phone jack for system control by phone
and central station monitoring.
Locate the RJ-31X jack (CA-38A in Canada) no further than five feet from the panel.
The panel must be connected to a standard analog (loop-start) phone line.
For full line seizure, install an RJ-31X phone jack on the premises phone line so the panel is
ahead of all phones and other devices on the line. This allows the panel to take control of the
phone line when an alarm occurs even if the phone is in use or off-hook.
If an analog line is not available, contact your customers' telecommunications specialist and
tell him/her you need an analog line off the phone switch (PBX mainframe) or a 1FB (stan-
dard business line).
¾
To connect a phone line to the panel using an
RJ-31X/CA-38A jack:
1. Run a 4-conductor cable from the TELCO protector block to the jack location (see A in
Figure 16).
2. Connect one end of the cable to the jack (see B in Figure 16).
Panel Terminals
Optional Switch
with Magnet
2k Ohm EOL
Resistor 49-454
(Locate at Last Device)
LCD/VFD Touchpads