Open Caveats

Release Notes for the NSS2000 Series Firmware Version 1. 1 6
For more information about upgrading the firmware, see the
Administration Guide
These are the open caveats for this release.
CSCsv34635
When the NSS is running over a network that is on a different subnet, a user
cannot mount a CIFS connection by using a hostname.
The workaround is to mount the CIFS connection by using an IP address.
CSCsv34808
When an unexpected power cycle occurs on the NSS, the time might be
corrupted on the NSS. This only applies if the time is set manually, not by
using NTP.
When this occurs, a pop-up alert window appears when you access
Configuration GUI after the unexpected shutdown.
The workaround is to manually check the time in the GUI. From the Manager
Menu, click Admin
CSCsv34900
If a data write operation is in progress, and the system power is interrupted,
data stored in a degraded RAID1 or RAID5 array might become
inaccessible. This is common to all NSS systems using software RAID
implementations.
These are the workarounds:
-
Replace the failed drives in the degraded arrays as soon as possible, as
failed RAID arrays can result in complete loss of all user data.
-
Use the degraded mode management feature to limit the amount of time
that a RAID array will run in the degraded state.
-
Implement a backup power strategy by using a UPS or RPSU backup
power system.
available on Cisco.com.
Time and correct the time if necessary.
 