Main
Sub code
Sub code
code
(1)
(2)
D5
02
ss
2-2-13.

Main Code D6

When abnormality of the internal memory was detected at the power-off, the following error occurs.
Main
Sub code
Sub code
code
(1)
(2)
D6
01
ss
D6
02
ss
2-2-14.

Main Code D7

When abnormality of the internal memory (MDC-21 board) was detected at the power-on, the following error occurs.
Main
Sub code
Sub code
code
(1)
(2)
D7
01
ss
D7
02
ss
PWS-4500
Error message
Description
SLOT Mx INTERFACE
Communication with the internal memory is impossi-
ERROR2
ble. This internal memory cannot be used as it is. When
the error occurs each time the power is turned on, the
unit or the internal memory may be defective.
Error message
Description
SLOT Mx UNMOUNT
An error occurred in the internal memory interface sec-
ERROR1
tion at the power-off sequence. This internal memory
may have been unusable. When "ERROR-D601ss" oc-
curs each time the power is turned off, the internal
memory must be salvaged.
SLOT Mx UNMOUNT
An error occurred in the internal memory interface sec-
ERROR2
tion at the power-off sequence. This internal memory
may have been unusable. When "ERROR-D602ss" oc-
curs each time the power is turned off, the internal
memory must be salvaged.
Error message
Description
SLOT Mx MOUNT ER-
An error occurred in the interface section when the in-
ROR1
ternal memory was connected to the system. When
"ERROR-D701ss" occurs each time the power is
turned on, the internal memory must be salvaged.
SLOT Mx MOUNT ER-
An error occurred in the interface section when the in-
ROR2
ternal memory was connected to the system. When
"ERROR-D702ss" occurs each time the power is
turned on, the internal memory must be salvaged.
Probable cause 1: IC400 on MEC-40 board
Probable cause 2: MDC-21 board
Protected operation: The unit does not take any
new action.
Probable cause 1: IC400 on MEC-40 board
Probable cause 2: MDC-21 board
Protected operation: None (After the time-out,
this unit shuts down. )
Probable cause 1: IC400 on MEC-40 board
Probable cause 2: MDC-21 board
Protected operation: None (After the time-out,
this unit shuts down. )
Probable cause 1: IC400 on MEC-40 board
Probable cause 2: MDC-21 board
Protected operation: The unit does not take any
new action.
Probable cause 1: IC400 on MEC-40 board
Probable cause 2: MDC-21 board
Protected operation: The unit does not take any
new action.