Server Uid Led - Hitachi HA825 G3 Series User Manual

Advanced server
Table of Contents

Advertisement

Item
1
2
3
4
1
When all LEDs flash simultaneously, a power fault has occurred. For more information, see Front panel LED power fault codes.
2
Facility power is not present, power cord is not attached, no power supplies are installed, power supply failure has occurred, or the front
I/O cable is disconnected.
3
If the health LED indicates a degraded or critical state, use iLO to

Server UID LED

The UID LED is used to locate a particular server when it is deployed in a dense rack with other equipment. Activating the
UID LED helps an on-site technician to quickly identify a server for maintenance tasks.
Description
Power On/Standby button and
1
system power LED
1
Health LED
1
NIC status LED
1
UID button/LED
Status
Definition
Solid green
System on
Flashing green
Performing power-on sequence
Solid amber
System in standby
No power present
Off
Solid green
Normal
Flashing green
iLO is rebooting
Flashing amber
System degraded
System critical
Flashing red
Solid green
Linked to network
Flashing green
Network active
Off
No network activity
Solid blue
Activated
Flashing blue
1 flash per second—Remote
management or firmware upgrade in
progress
4 flashes per second—iLO manual
reboot sequence initiated
8 flashes per second—iLO manual
reboot sequence in progress
Off
Deactivated
review the system health
2
3
3
status.
Component identification
10

Advertisement

Table of Contents
loading

Table of Contents