Item
LED
4
SFP Port 2 Link/Activity
LED
5
System status LED
Fan numbering
To provide sufficient airflow to the system, the server is populated by four fans by default. There are a total of six fans.
The fans can either be standard, single-rotor fans or high performance, dual-rotor fans. Mixed fan configuration is not
supported.
The arrow points to the front of the server.
Fan and heatsink requirements
CAUTION: To maintain proper system cooling, install the correct fan and heatsink types required for specific
hardware configurations.
•
Using NVMe drives requires high performance fans.
•
The maximum processor support with a midplane cage installed is 300 W.
Status
Description
Flashing green
Passing traffic; flashing frequency indicates traffic intensity
Solid amber
Link fault
Off
A link has not been established
Solid green
Valid Ethernet link
Flashing green
Passing traffic; flashing frequency indicates traffic intensity
Solid amber
Link fault
Off
System is not powered
Solid amber
Power is up, software has not booted yet
Solid green
System is up and fully operational
Component identification