Makita GMP01 Instruction Manual page 19

Cordless backpack mist blower
Table of Contents

Advertisement

Available languages

Available languages

2.
Remove the standard nozzle by turning the nozzle
counterclockwise using the wrench.
1
Fig.40
► 1. Wrench 2. Standard nozzle
3.
Remove the O-ring from the standard nozzle, and
then attach it to the ULV nozzle.
1
Fig.41
► 1. O-ring 2. Standard nozzle 3. ULV nozzle
4.
Attach the ULV nozzle by turning the nozzle clock-
wise using the wrench.
Fig.42
► 1. Wrench 2. ULV nozzle
5.
2
2
Fig.43
► 1. Screw 2. End nozzle
3
2
1
19 ENGLISH
NOTICE:
Do not tighten the nozzle too much.
The recommended tightening torque is approxi-
mately 1.0 N•m. Tightening the nozzle too much may
damage the mounting part for nozzle.
Attach the end nozzle, and then tighten the screw.
1
2

Advertisement