Alarm Recording

The HSR-X200/X200P automatically starts alarm
recording when it detects the specified trigger.
For the trigger, you can select the following alarm
signals independently or in combination:
1. External alarm input
2. Internal alarm generated by the built-in activity
detection sensor when it detects a change in
luminance at the specified points on the camera
input picture.
By activating pre-alarm recording, the HSR-X200/
X200P continues recording the camera input,
overwriting the data for the specified duration. When
the trigger is detected, the HSR-X200/X200P switches
to regular alarm recording. This enables you to check
the image a certain time before the trigger is actually
detected.
Note
When a multiplexer is in use, you can only select
external alarm input for the trigger and must select a
certain channel (camera number) to be recorded.
For channel selection, see "Multiplexer Channel Selection"
on page 35(GB).

Settings for Alarm Recording

For alarm recording, you may set the following
requirements, including the trigger.
Use ALARM REC MODE SET of MAIN MENU 1.
<ALARM REC MODE SET>
PICTURE QUALITY
FRAME/FIELD RECORDING
AUDIO RECORDING
ALARM RECORDING
REC CYCLE :
0.33 SEC, DURATION : 40 SEC
PRE-ALARM RECORDING
REC CYCLE : A 0.05 SEC, DURATION : 1 MIN
c (1010 ALARMS CAN BE RECORDED)
ALARM TRIGGER
ACTIVITY SENSOR
PICTURE QUALITY
FRAME/FIELD RECORDING
AUDIO RECORDING ON/OFF
REC CYCLE
These items can be set the same as for normal
recording.
: SUPER
: FIELD
: ON
: MODE1
: ON
: ALARM AND SENSOR
c
ALARM RECORDING
Select the mode to execute alarm recording.
MODE1: To execute alarm recording regardless of
timer recording
MODE2: To execute alarm recording only while timer
recording is in progress
MODE3: To execute alarm recording only while timer
recording is not in progress
MODE4: To execute alarm recording during the
period(s) set for timer recording (timer recording
itself is not performed)
Set to OFF when no alarm recording is required.
DURATION
Set the duration for alarm recording.
You may select from among 1S/2S/5S/10S/20S/40S/
1M/2M/3M/4M/5M/10M/15M/CC.
With CC, recording is made as long as the alarm signal
is ON.
PRE-ALARM RECORDING
To perform pre-alarm recording, set PRE-ALARM
RECORDING to ON, and select REC CYCLE and
DURATION of pre-alarm recording.
The values selectable for DURATION depend on the
selected REC CYCLE value.
See "REC CYCLE and DURATION values of pre-alarm
recording" on page 27(GB).
Note
You cannot highlight PRE-ALARM RECORDING on
the display with ALARM RECORDING set to OFF.
ALARM TRIGGER
Select the trigger.
ALARM: External alarm input
SENSOR: Internal alarm generated by the built-in
activity detection sensor
ALARM AND SENSOR: Simultaneous occurrence
of external and internal alarms
ALARM OR SENSOR: Occurrence of either an
external or internal alarm
Setting procedure
1
Press the MENU button to display MAIN MENU 1
on the monitor screen.
2
Turn the Jog dial to highlight 8. ALARM REC
MODE SET and turn the Shuttle dial clockwise.
The ALARM REC MODE SET display appears.
25