Attaching Front Guide Hose (Optional Equipment For Use With Autofeed Unit); Advance Display And Control Panel Setting Cable Information; Monitoring And Recording Drain Cleaning Information - RIDGID K-4310 FXP Manual

Table of Contents

Advertisement

Available languages

Available languages

K-4310 FXP Drum Machine
with. The setting of the unit can be checked by looking
at the front of the unit, see Figure 9. The slot aligns with
the cable size.
Grease
Fittings
Cam Slot
Figure 9 – Checking AUTOFEED Unit Setting
To change setting between
1. Loosen the AUTOFEED adjustment knob.
2. Use a flat blade screwdriver in cam slot to rotate both
cams (see Figure 9). If using
setting.
Attaching Front Guide Hose (Optional
Equipment for use with AUTOFEED Unit)
1. Pull approximately 4' of cable from the drum.
2. Slide Front Guide Hose over the cable, adapter end
first.
3. Pull plunger pin head up and place adapter over the
mounting collar on the AUTOFEED unit. Make sure
plunger pin locks into the hole in the mounting collar.
(Figure 10).
Hole
Plunger
Pin
Figure 10 – Attaching Front Guide Hose
10
10
For 5/8" and 11/16" Cable
For 3/4" Cable
/
" and ¾".
5
8
/
" cable, use the
11
5
16
Advance Display And Control
Panel
Setting Cable Information
The K-4310 FXP Drum Machine is equipped to monitor
and display the cable travel in and out of the drum.
To work properly, cable/drum information must be en-
tered using the control panel (or RIDGID Link App, if
connected).
1. Move the main ON/OFF switch to ON position.
2. Toggle Between cable size selection using Cable
Diameter Selector Button (see Figure 2/3). When
selected, the screen will return to home screen after
3 seconds.
3. Toggle between cable length selection using Cable
Length Selector Button (see Figure 2/3). When se-
lected, the screen will return to home screen after 3
seconds.
4. Move the main ON/OFF switch to OFF position.
NOTE: These settings will be saved and will not need
updated unless a different drum/cable is used.
This feature does not work with cables not listed
on the display. Incorrect cable information will
decrease the cable travel accuracy.
/
"
8
a. Cable Diameter Screen
Figure 11 – Setting Cable Parameters
Monitoring And Recording Drain
Cleaning Information
The advance display and control panel allows monitoring
of the cable travel in and out of the drum. The zero point
is set by depressing the cable travel reset "Zero" button.
See Figure 2. For best results the calibration should
be performed with no more than 6" (150 mm) of cable
outside the drum. Remember that cable travel is always
relative to the zero point. If the cable is reset with more
than 6" (150 mm) out of the drum the cable travel reading
may be off by more than +/-2' (+/- 0.6 m).
Confirm that the cable information on the Control Panel
matches the cable being used. Incorrect cable informa-
tion can affect the accuracy of the travel readings. Do not
let the use or monitoring of the control panel distract you
from controlling the cable and drain cleaning process.
Inattention to the cable and drain cleaning process can
b. Cable Length Screen
999-995-420.10_REV A

Advertisement

Table of Contents
loading

Table of Contents