Stopping Measurement; Turning Off Power - Casio CMT-S20R-AS User Manual

Motion sensor
Table of Contents

Advertisement

7.
Slide the clip slide lock downwards to lock it.
The slide lock uses a 2-step lock mechanism. If your running pants are too
thick to push the slide lock all the way in, stop the slide lock when you feel the
first click (1-step lock).
IMPORTANT!
• When locking the clip, do not use excessive force to press the slide lock in.
Doing so creates the risk of damage to the sensor unit and your running pants.
• The sensor unit can fall off of your running pants if it cannot be secure using
the slide lock for some reason. Be sure to wear running pants that allow you to
lock the slide lock.
2-step lock
8.
Start running.
IMPORTANT!
• Ongoing measurement will stop if the battery goes dead.
Before starting measurement, use the Runmetrix app to check the battery
level, and charge the battery if necessary.
• If the memory becomes full during measurement, the oldest data will be
deleted to make room for the new data. Before starting a measurements, you
can use the Runmetrix app to check the remaining recording capacity and
transfer data to the app if necessary.
• You can use the Runmetrix app to enable or disable the "Auto Pause" setting.
(Initial Default: Disabled)
• You can use the Runmetrix app to change the "Auto Lap" setting. (Initial
Default: 1 km)
• The sensor unit will turn off automatically if it becomes hot.

Stopping Measurement

9.
Slide the clip slide lock upwards to unlock it.
10.
Remove the sensor unit from your running pants.
IMPORTANT!
• Do not attempt to remove the sensor unit from your running pants while the clip
is locked with the slide lock. Doing so creates the risk of damage to the sensor
unit and your running pants. Release the slide lock before removing the sensor
unit from your running pants.
11.
Press the sensor unit button twice in succession (double-click).
Release the button when you hear a beep, and the LED changes from
flashing to lit. This indicates that measurement is stopped.
• Measurement data is transferred to your phone and then automatically
uploaded to the server. Depending on contract conditions with your service
provider, this operation may cause normal communication charges to be
incurred by you.
• To restart measurement, perform steps 4 through 8 of the above
procedure.

Turning Off Power

12.
Hold down the sensor unit button for about two seconds.
Keep the button depressed until you hear one beep, and then, two seconds
later, two more beeps. This indicates that power is turned off.
• If the LED lights red for about two seconds, it means that remaining battery
power is low. Charge the sensor unit. Use the Runmetrix app to check the
remaining battery charge.
1-step lock
9

Advertisement

Table of Contents
loading

Table of Contents