  • Page 1 Zip HydroTap ® Installation and Operating Instructions BCS100/75 and BCS Series Scan QR Code to download the latest version of this document. English French 802265US v1.27 06.21 BCS, BCS100-75 Install Instructions Page 1 of 36...
  • Page 2 Faucet options The HydroTap appliance series offers a range of interchangeable faucets to suit the customer’s needs. For ease of installation, it is recommended to fit the faucet before installing the Command Center. The installation procedure for each of the faucets is detailed in the Faucet Installation instruction book supplied with the faucet.
  • Page 3: Table Of Contents

    Index HydroTap Specifications Installation Checklist ........................4 General Product Features ......................5 Important Safety Instructions ....................... 6 Warnings and Regulatory Information ..................7 Major Components and Accessories ................... 8 Technical Specification ........................ 9 Before Installation and Site Requirements ................... 10 Installation Procedure STEP 1 - Fit the faucet to the benchtop or sink, before installing the Command Center.
  • Page 4: Installation Checklist

    Installation checklist Before Installation: Read the instructions and check if there is adequate space to mount all of the components. Note: Not all fittings are supplied with the appliance kit. Isolation valves are not supplied. Check the mains water pressure is between 250 - 700 kPa (37 - 100 psi). Products are rated for either 110-120V, 60Hz OR 230V, 50Hz AC installations.
  • Page 5: General Product Features

    General Product Features Thank you for purchasing a Zip HydroTap. Please read and follow these instructions carefully to ensure safe and trouble free service. What is the Zip HydroTap ? The Zip HydroTaps are electronically controlled, filtered, Boiling, Chilled and Sparkling water, drinking systems for kitchens and tea rooms.
  • Page 6: Important Safety Instructions

    Lifting Take care when lifting the Zip HydroTap Command Center. Some units may exceed safe lifting limits. If you feel this is beyond your personal capabilities, please seek assistance with the lift. The weights of the units are marked on the packaging.
  • Page 7: Warnings And Regulatory Information

    Important Safety Instructions WARNINGS 1. The Zip HydroTap Command Center must be earthed. The resistance of the earth connection from each exposed metal part must be less than 1 ohm. 2. All Installation and service work must be completed by trained and suitably qualified Tradespeople.
  • Page 8: Major Components And Accessories

    Major components and accessories Parts supplied Description Accessories Description 1x faucet with hoses Softener (Classic Faucet and head assembly shown) Font (Drip Tray) 1x HydroTap Kit for Arc & Cube Command Center models with air and water 93580US (Chrome) filters Font (Drip Tray) Kit 1x Mains water for Classic Models...
  • Page 9: Technical Specification

    Technical Specifications Models*: BCS100/75 (230V) - Classic XX BCS100/75 (230V) - CUBE XX BCS100/75 (230V) - ARC XX BCS100/75 (230V) - Celsius AIO XX BCS (230V) - Classic XX BCS (230V) - CUBE XX BCS (230V) - ARC XX BCS (230V) - Wave XX BCS (230V) - Celsius AIO XX BCS (110-120V) - Classic XX BCS (110-120V) - CUBE XX...
  • Page 10: Before Installation And Site Requirements

    Before Installation Before installing ensure that the following have been provided at the Installation site: • Review all the technical specifications. • Ensure the undersink can support the product weight when full of water (allow an extra 5 kg (11 lb) when full).
  • Page 11: Section 2 - Ventilation

    Section 2 Ventilation When installing air flow ducts, the following tools will be required: • Jigsaw and a 12mm (½”) Drill • Keyhole or Wall Board saw. 2.1 Ventilation for All Models Proper air circulation must be provided for all models. The system will operate correctly only if the recommended air gaps are achieved during installation.
  • Page 12: Cabinet Air Circulation

    Ventilation 2.3 Alternative Ventilation If the air flow, using the silicone door buffers, is insufficient, it will be necessary to fit a standard HydroTap vent kit, which ensures heat dissipation through natural convection via installed vents. For high use applications, where the cabinet space temperature is near 35°C (95°F) or higher, the inlet vent (See Item B below) and silicone buffers, need to be fitted.
  • Page 13 Ventilation Typical Cut-out procedure for 1. Mark out and cut the air inlet and door outlet holes as shown 2. Ensure the air inlet vent and air outlet vent are positioned at opposite ends of the same cabinet space. 3. Fit the inlet vent, as shown and secure with 5 screws 4.
  • Page 14: Section 3 - Co Cylinder

    Section 3 - CO Cylinder STORAGE WARNING: gas cylinders must be installed in an open plan area or in an enclosed room, with a volume no less than 50 cubic metres (65 cubic yards) for each 2.6kg (6lb) of stored gas. If more than 1 gas cylinder containing is present within the same location, the recommended ventilated area should be in proportion to the number of gas cylinders stored in that location.
  • Page 15 Regulator This gauge shows the pressure in the bottle and This gauge shows the adjustable limit (3.0±0.1 bar, indicates when the bottle is empty. Initial bottle or 39±1 psi) required for the HydroTap to function pressure will be 35-40 bar (507-580 psi) . correctly Green zone Relief...
  • Page 16: Section 4 - Command Center Installation

    The diverter bypass valve allows the user to choose to have the boiling water treated either by the internal or by an optional external water treatment device. This diverter valve is located at the rear panel of the Zip HydroTap Command Center (see the image below).
  • Page 17: Hose And Tube Fitting

    Installation Instructions Hose and tube fitting 90° Bend end of Braided Hose • Remove all caps from the top of the Command Center Braided hose for Mains Water Supply (except the mixer caps) • Only remove the mixer caps if a mixer faucet is to be fitted.
  • Page 18: Model Bcs Installation And Connection

    Installation Instructions Model BCS 100/75 Note: Note: the hoses need to hoses need to have a constant have a constant downward downward gradient to the gradient to the HydroTap to HydroTap to allow all water allow all water to drain back to drain back into the tanks.
  • Page 19: Model Bcs Celsius All-In-One (Mains) Installation And Connection

    Installation Instructions Model BCS 100/75 Celsius All-In-One (Mains) Note: Note: the hoses need to hoses need to have a constant have a constant downward downward gradient to the gradient to the HydroTap to HydroTap to allow all water allow all water to drain back to drain back into the tanks.
  • Page 20: Section 5 - Commissioning

    Section 5 Commissioning The HydroTap is now ready to be commissioned. • Turn ON the water and gas and check for any leaks. • Turn the power ON at the power outlet and at the side of the Command Center •...
  • Page 21: Boiling Calibration

    Commissioning Stop cock operation 1. Turn the flush line stop cock ON (See diagram). 2. Press [Start] and allow at least 10 liters (2.6 gallons) of water to flush through the filter. OPEN 3. The product details will be displayed in the screen. 4.
  • Page 22: Sensor Calibration

    Conditioning Procedure Zip HydroTap Command Centers are sanitized during manufacturing and require flushing before normal use. 1. Dispense 6 liters (1.6 gallons) of boiling water from the boiling outlet of the HydroTap (equivalent to 2 complete tanks full of water) 2.
  • Page 23: Backflow Prevention

    Commissioning Backflow Prevention All HydroTap models that have sparkling/carbonated water functionality include the following integral Backflow Prevention. Main Water Inlet The Dual Check Valve (DCV) on the Mains Water inlet connection is designed to ensure a uniform direction of flow throughout the HydroTap.
  • Page 24: Troubleshooting Table

    Flow Sensor Fault Internal fault Call Zip Service Contact your local service provider or Zip’s US distributor Culligan International Company on US Toll Free 1-833-233-2358 for assistance, service, spare parts or enquiries. End of Life Disposal In order to help preserve our environment we ask that you dispose of this product correctly. This product should not be treated as domestic waste, but should be taken to a dedicated recycling center for electrical and electronic equipment.
  • Page 25: Performance Data Sheets

    67 Allingham Street, Condell Park NSW 2200 Australia Distributed in US and Canada by: Culligan International Company Call Zip’s US distributor Culligan International Company on US Toll Free 1-833-233-2358 for assistance, service, spare parts or enquiries. Testing Conditions and Results:...
  • Page 26 67 Allingham Street, Condell Park NSW 2200 Australia Distributed in US and Canada by: Culligan International Company Call Zip’s US distributor Culligan International Company on US Toll Free 1-833-233-2358 for assistance, service, spare parts or enquiries. Testing Conditions and Results:...
  • Page 27 67 Allingham Street, Condell Park NSW 2200 Australia Distributed in US and Canada by: Culligan International Company Call Zip’s US distributor Culligan International Company on US Toll Free 1-833-233-2358 for assistance, service, spare parts or enquiries. Testing Conditions and Results:...
  • Page 28 67 Allingham Street, Condell Park NSW 2200 Australia Distributed in US and Canada by: Culligan International Company Call Zip’s US distributor Culligan International Company on US Toll Free 1-833-233-2358 for assistance, service, spare parts or enquiries. Testing Conditions and Results:...
  • Page 29 67 Allingham Street, Condell Park NSW 2200 Australia Distributed in US and Canada by: Culligan International Company Call Zip’s US distributor Culligan International Company on US Toll Free 1-833-233-2358 for assistance, service, spare parts or enquiries. Testing Conditions and Results:...
  • Page 30 67 Allingham Street, Condell Park NSW 2200 Australia Distributed in US and Canada by: Culligan International Company Call Zip’s US distributor Culligan International Company on US Toll Free 1-833-233-2358 for assistance, service, spare parts or enquiries. Testing Conditions and Results:...
  • Page 31 67 Allingham Street, Condell Park NSW 2200 Australia Distributed in US and Canada by: Culligan International Company Call Zip’s US distributor Culligan International Company on US Toll Free 1-833-233-2358 for assistance, service, spare parts or enquiries. Testing Conditions and Results:...
  • Page 32 67 Allingham Street, Condell Park NSW 2200 Australia Distributed in US and Canada by: Culligan International Company Call Zip’s US distributor Culligan International Company on US Toll Free 1-833-233-2358 for assistance, service, spare parts or enquiries. Testing Conditions and Results:...
  • Page 33 67 Allingham Street, Condell Park NSW 2200 Australia Distributed in US and Canada by: Culligan International Company Call Zip’s US distributor Culligan International Company on US Toll Free 1-833-233-2358 for assistance, service, spare parts or enquiries. Testing Conditions and Results:...
  • Page 34: Warranty

    Zip Customer can opt to extend the Zip Product warranty by one (1) year, making the total Limited Warranty period two (2) years. In order to extend the warranty to two (2) years, the Zip Customer must register their product with Zip.
  • Page 35 Dispute Resolution If the Zip Customer is not satisfied with the warranty service, he or she must submit a claim in writing to Zip’s Dispute Settlement Representative at Culligan International Company, d/b/a Zip Water, 9399 W Higgins Rd, Rosemont, IL 60018.
  • Page 36 Images in this booklet have been modified and may not be true representations of the finished goods. The terms “Zip” and “HydroTap” are registered trade marks of Zip Water (Aust) Pty Ltd. BCS – Classic XX, BCS – ARC XX, BCS – CUBEXX, BCS – Celsius AIO XX, BCS100/75 – Clas- sic XX, BCS100/75 –...