Advertisement

User Guide
HydroTap G5
®
UltraCare BCU 40
Australia
UK
Visit our website to download the manuals
1
807041 v1.00 03.21 HydroTap G5 UltraCare User guide

Advertisement

Table of Contents
loading

Summary of Contents for Zip HydroTap G5

  • Page 1 User Guide HydroTap G5 ® UltraCare BCU 40 Australia Visit our website to download the manuals 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 2 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 3: Table Of Contents

    4.3 Cleaning ..............34 4.4 UV-C module ............35 4.5 Safety solenoid ............36 4.6 Chilled hose and tap tube ........37 4.7 In-field sanitisation..........38 Sanitisation procedure ..........39 Maintenance log .........41 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 4 • Scan the QR code and follow the on screen steps to register your product. MAIN MENU 12:12 PM General System Safety & Energy Settings Settings Security Saving Info & Product Register Service Logs Serial No. Product Technician 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 5: Section 1: Safety

    Download & read the complete Command Centre installation instruction manual and user guide. Read and use the instructions supplied with individual kit components for a safe use and installation of replacement consumables. 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 6: Section 2: Tap Operation

    SECTION 2: Tap operation Classic page 7 Touch-Free Wave page 8 HydroTap Mixer Taps page 10 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 7: Classic

    SAFETY FLASHING SLOWLY FLASHING SLOWLY Water temperature is not Change filter. at set point FLASHING QUICKLY System fault Dispense options Use boiling, chilled, sparkling, or ambient lever to dispense your water choice. 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 8: Touch-Free Wave

    Filter needs replacing, CO2 warning (G5), unit is in an error mode (refer to Command Centre screen). WHITE Flashing rapidly Sensors calibrating when power is first applied to the tap. Allow 10 seconds. 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 9 Boiling Boiling Water Chilled Ambient Side + Rear sensor: Bottle fill (timed dispense) Sparkling Top + Rear sensor: Bottle fill (timed dispense) 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 10: Hydrotap Mixer Taps

    SECTION 2: Tap operation 2.3 HydroTap Mixer taps Controls mixed water Cold Lift and rotate the lever to dispense mixed warm water. 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 11: Section 3: Command Centre Screen

    Saving Info & Product Register Service Logs Serial No. Product Technician Touch the language icon to navigate to the language screen. Touch the relevant icon to choose the language. (To go back) 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 12 You will hear the sound of an internal “click” as the HydroTap Command Centre turns ON or OFF. When OFF, all functions are disabled including heating, chilling, filling and dispensing. Turning the power back ON will reset the system of any faults. 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 13: Home Screen

    A warning icon is shown when the filter needs to be replaced. See page 27. Energy saving settings View or modify the current active timers and sleep mode actions. See page 27. 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 14: Main Menu

    Touch each icon to access further options. MAIN MENU 12:12 PM General System Safety & Energy Settings Settings Security Saving Info & Product Register Service Logs Serial No. Product Technician 3.4 General settings Language 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 15 Touch the text boxes on the screen and then press + and - to set the current date and time. Press the tick to confirm and save. Network Connect to Wi Fi (available with optional Zip Assist Kit). 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 16: System Settings

    Settings Settings Security Saving Info & Product Register Service Logs Serial No. Product Technician SYSTEM SETTINGS 12:12 PM Filter Temp Dispense Settings Settings Times Light Quiet Advanced System Sensor Mode Settings Restart 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 17: Filter Settings

    See page 31 for filter change instructions. Flush line tap Open filter door, uncoil flush line. Direct flush line into bucket. Open flush line tap. Flush line tap open 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 18 The screen will show the filter has been flushed. Close the flush line tap, return the flush line to the filter compartment and close door. Flush line tap closed Reset the filter counter (see page 19). 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 19 12:12 PM Life (months) Usage (days) Life (litres) Usage (litres) 04000 INTERNAL FILTER LIFE 12:12 PM UV Unit Life (months) UV Unit Life (days) Activated LED Life (Hrs) Activated LED Usage (Hrs) 2500 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 20: Temperature Settings

    Up to 6% less energy in standby is consumed with a 98ºC set point, rather than 100ºC. A warning icon will appear when setting boiling set point temperatures that are subject to pump cavitation. 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 21 External Booster For selected commercial Boiling models, an external booster is supplied or may be purchased as an upgrade to increase Boiling capacity. Ensure the correct selection is made, for optimum performance. 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 22: Dispense Times

    This will calibrate the light sensor which will allow the system to go to sleep when it is dark. Before we start, the room should be in a typical ambient lit environment. Remove any object away from the tap. 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 23: Quiet Mode

    There will be a 150 millisecond delay before water is dispensed. Power Pulsing Mode Applies a closer tolerance to the set temperature, to ensure hot water is maintained as closely as possible to the set point. 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 24: Advanced Settings 2 (Wave Tap Only)

    Bottle fill is disabled. 3.5.8 System restart Touch the top circle, then the bottom circle to power down and restart the system. Use this function to reset faults or to reset the settings access password. 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 25: Safety & Security

    • Disabled: boiling water can be dispensed without the need to touch/tap the safety button. Hot isolation 3 slow safety button presses are required prior to dispensing. 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 26: Passcode Protect

    Users will be prompted for this passcode when attempting to access settings. Create a 4-digit passcode and re-enter, as prompted. The passcode will be deactivated if the HydroTap is reset (powered off and on again). 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 27: Energy Saving

    Recalibrate the light sensor after selecting sleep when “it gets dark”. Ensure the ambient light is typical for operating conditions (see page 22). SLEEP WHEN 12:12 PM It gets Not used dark in 2 hours 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 28: On/Off Timer

    The off/on timer can be set to the same time every day, on a range of days (weekdays/weekends), or by individual days. SET TIMER 12:12 PM Everyday Weekdays / Weekends Individual days 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 29: Energy Use

    Track energy usage of your HydroTap by viewing the total energy consumed and the energy consumed since the last energy use reset. ENERGY USE 12:12 PM Total (kWh) 00000.0 Last Period (kWh) Date of Reset 000.0 01/01/2020 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 30: Info & Logs

    View the system information. ABOUT SYSTEM 12:12 PM Title Info Module: BCS100 App. revision: 017-H5v0.1.xx Serial No: 0000000000000 Product No: H500xx000AU Calibration: 50L Filtered: Wi-Fi: BS 0.00 FW 0.00 MAC Address: 00:00:00:00:00:00 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 31: Section 4: User Maintenance

    Place a cloth or towel under the filter cartridge before removing. Water will drip as the cartridge is removed. Unpack replacement cartridge and remove sanitary cap. Write today’s date on the label. 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 32 Clean up and dispose of old cartridge and packaging. If the HydroTap is switched off for a long period of time (e.g. more than a weekend), run water through the chilled water outlet for at least 60 seconds before consumption. 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 33: Air Inlet Filter Maintenance

    Gently dry with a cloth or towel. Maintain at least a 50mm air gap in front of the air inlet screen at all times. Take care to keep the air inlet clear of blockage. 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 34: Cleaning

    Touch-Free Wave Tap. This could cause permanent malfunction and void warranty. Do not use self-drying disinfectant sprays. Dried cleaning fluid may affect function of the sensors. 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 35: Uv-C Module

    15mm over the fittings. Insert new UV-C module into the port marked CHILLED OUT. Plug USB cable from UV-C module into the port at the side of the Command Centre. Next, replace the safety solenoid. 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 36: Safety Solenoid

    Turn ON power and water. Check for and repair any water leaks. Re-fit the back panel of the Command Centre and reposition it in place. Next, reset UV-C module usage. See page 18. 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 37: Chilled Hose And Tap Tube

    9. Connect the other end of the new hose to the chilled water outlet of the HydroTap Command Centre. Push the end of the hose into the fitting as far as it can go. Pull back to test the connection. 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 38: In-Field Sanitisation

    • If the sanitising fluid contacts your skin, wash off with soap and water. • If the sanitising fluid contacts your eyes, flush continuously with fresh water. • Sanitising fluid will remove colour. Clean any spill immediately with fresh water. 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 39: Sanitisation Procedure

    11. Remove the foil wrap from the CleanOxide tablets. Place 2x 0.5g CleanOxide tablets into the sanitising canister. 12. Connect the mains water supply hose from the HydroTap to the top of the sanitising canister. 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 40 0.8 ppm (mg/L) 25. Removing the sanitising connector (this may be re-used) and re-install the UV-C module. 26. Dispense boiling water to empty the boiling tank. Sanitisation is complete. 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 41: Maintenance Log

    • Replace silicone hoses and tablets, 0.5g outlet tube • Safety solenoid • Change water filter • UV-C module • Clean air inlet filter 96863 (809283) • Sanitise system • Tap top kit 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 42 84 months (7y) Service or 84000 litres 90 months (7.5y) Filter or 90000 litres change 96 months (8y) Service or 96000 litres 102 months (8.5y) Filter or 102 000 litres change 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 43 Filter or 114 000 litres change 120 months (10y) Service or 120 000 litres 126 months (10.5y) Filter or 126 000 litres change Other services Time from Type Date Name Sign installation 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...
  • Page 44 Postal: Locked Bag 80, Bankstown 1885, Australia (+612) 9796 3100 | Free Call (Aust): 1800 947 827 www.zipwater.com AU02691 Zip Water UK Trafalgar House Rash’s Green, Dereham, Norfolk NR19 1JG 0345 6 005 005 sales@zipindustries.co.uk specify.zipwater.co.uk 807041 v1.00 03.21 HydroTap G5 UltraCare User guide...

Table of Contents