Sm Maximum Length Ignore; Sn Scanner Configuration - Honeywell E-Class Series User Manual

Table of Contents

Advertisement

Parameter:
Value / Range:
Units / Interpretation:
Command Equivalent:
Value
A
H
P
C
T
N

SM Maximum Length Ignore

This command controls recognition of the <STX>M command.
Parameter:
Value / Range:
Units / Interpretation:
Command Equivalent:

SN Scanner Configuration

This command configures the linear scanner.
Parameter
Value / Range:
120
SL
A, H, P, C, T, N
See table below.
N/A
Stop Location
Automatically sets the stop location. Installed options will be
"auto-sensed" and the appropriate stop position will
automatically be set. Host commands are ignored.
Sets stop position according to options installed. If no options
are installed the printer sets stop location to the next label's start
of print. Host commands will override. The stop location (present
distance) may be controlled dynamically by the host using the
<STX>f or <STX>Kf commands. This selection has the same effect
as <STX>KD Ignore Host Distance bit value 0.
Sets the stop location at approximately two millimeters behind
the peel bar edge, a nominal peel position. The Present Sensor
status and this setting are independent.
Sets the stop location to a nominal cut position. For die-cut
media, the position is just following the end of the label. The
cutter status and this setting are independent.
Sets the stop location at the tear bar.
Sets the stop location to the start of the next label, equivalent to
setting the <STX>KD Ignore Host Distance bit value 1.
SM
0, 1
0 = Normal processing, 1 = Ignore
N/A
SN
B, C, D, H, M, V
DPL  Command Reference

Advertisement

Table of Contents
loading

Table of Contents