Honeywell E-Class Series User Manual page 108

Table of Contents

Advertisement

Value
Units/Interpretation
0 = No Reprint
1 = Standard
2 = Void and Retry
L
 
 
 
3 = Delayed Scan Fault
4 = Void Retry & Cont.
Void Distance (.10 -
D
2.00)
R
Retry Count (0 – 3)
88
Selection/Definition
Printing stops and a fault message is displayed. After the problem is
corrected, the label in process is not reprinted.
The default behavior. Printing stops and a fault message is dis-
played. After the problem is corrected, the label in process is reprin-
ted.
Depending upon the RETRY COUNT, one of the following actions
when faulted:
 
If the Retry Count has not been exceeded, "VOID" is printed on the
l
label in process and reprinting occurs automatically;
 
If the Retry Count has been exceeded, printing stops and a fault
l
message is displayed. After the problem is corrected, press the
FEED key to clear the fault. The label in process is reprinted; or,
 
If the CANCEL key is pressed, the operator has the option of can-
l
celing the reprint. To allow reprinting, press the ESCAPE Key; or, to
cancel reprinting, press the ENTER key (the entire label batch will
be cancelled by pressing the ENTER key again).
VOID will not be printed when insufficient text space exists (see
VOID DISTANCE, below) or if the fault occurs after the label reaches
its Present Distance at, or above, the TOF.
Increases throughput when barcodes reside near the trailing edge of
the label (in the direction of FEED).
If unreadable, the fault will occur after the next label prints. The
label immediately following a faulted label is not scanned for errors.
VOID AND RETRY and REPRINT are automatically disabled; the job
can only be cancelled.
VOID is printed on a faulted label, with reprint attempts occurring
automatically, until the RETRY COUNT has been exceeded and then
that label will be skipped (discarded) and printing will continue to
the next label in queue.
Sets the distance (.10 - 2.00) to backup the faulted label to print
"VOID" on its trailing edge, which also indirectly establishes the font
size of the void message.
Establishes the number of times a reprint will be attempted when
using the RFID or Scanner option; if the last label printed in this
count has been voided, a fault will be declared.
DPL  Command Reference

Advertisement

Table of Contents
loading

Table of Contents