Precision Platform 4022 Scanner
9-28
:
WARNING
2. Remove the covers as described in Subsection 9.1.7.
3. Check the belt tension and head alignment, as described in
Subsection 9.6.3, and adjust if necessary.
4. Manually move the heads such that the head carriage drive belt
connection to the carriage is adjacent to a belt support bracket.
5. Loosen the belt support adjustment bolts and move the belt
support bracket such that there is approximately 1/8" clearance to
the belt.
6. Make sure the belt support is not cocked, and tighten the
adjustment nuts.
7. Repeat steps 4 through 6 for all of the belt supports on both the
upper and lower beams.
8. Reinstall the beam covers as described in Subsection 9.1.7.
9. Record the maintenance in the scanner logbook.
10/18/07
To perform any maintenance, troubleshooting, or
replacement of components, ensure that power is
disabled at the breaker.
Scanner Maintenance
p/n: 6510020208