applied perpendicular against the belt. Tighten the motor bracket
fastening bolts and recheck the belt tension. Readjust belt tension if
necessary.
7. Move the encoder so that the pulley engages the motor belt and
turns when the belt moves. It should deflect the motor belt 1mm
(.03"). Tighten the encoder fasteners.
8. Reinstall the beam covers as described in Subsection 9.1.7.
9. Record the maintenance in the scanner logbook.