RM7800E,G,L,M
SPECIFICATIONS • ORDERING INFORMATION
ELECTRICAL RATINGS, see Table 1:
Voltage and Frequency: 120 Vac (+10/-15%), 50 or
60 Hz (+/- 10%)
Keyboard Display Module: 13 Vdc peak full wave
rectified (+20/-15%).
Terminal No.
Description
G
Flame Sensor Ground
Earth G
Earth Ground
L2(N)
Line Voltage Common
3
Alarm
4
Line Voltage Supply (L1)
5
Burner Motor
6
Burner Controller and Limits
7
Lockout/Running Interlock
8
Pilot Valve/Ignition
9
Main Fuel Valve
10
Ignition
F(11)
Flame Sensor
12
Firing Rate High Fire
13
Firing Rate Common
14
Firing Rate Low Fire
15
Firing Rate Modulate
16
Unused
17
Unused
18
Low Fire Switch Input
19
High Fire Switch Input
20
Preignition Interlock Input
21
Interrupted/Intermittent Pilot Valve/First Stage Oil Valve
22
Shutter
1
The RM7800 must have an earth ground providing a connection between the subbase and the control panel or the equipment. The
earth ground wire must be capable of conducting the current to blow the 20A fuse (or breaker) in event of an internal short cir cuit.
The RM7800 needs a low impedance ground connection to the equipment frame which, in turn, needs a low impedance connection
to earth ground. For a ground path to be low impedance at RF frequencies, the connection must be made by minimum length conduct ors
having maximum surface areas. Wide straps or brackets are preferred rather than leadwires. Be careful to ensure that mechanical ly
tightened joints along the ground path, such as pipe or conduit threads or surfaces held together with fasteners, are free of
nonconductive coatings and are protected against mating surface corrosion.
2
2000 VA maximum connected load to RM7800 Assembly.
3
Can also be 120 Vac, 1A pilot duty.
4
Can also be 65 VA pilot duty with motorized valve, 1150 VA inrush, 460 VA open, 250 VA hold.
5
Operating frequency chosen by RM7800 selection.
When purchasing replacement and modernization products from your 7800 SERIES distributor, refer to the TRADELINE® Catalog for
complete ordering number.
If you have additional questions, need further information, or would like to comment on our products or services, please write or phone:
1. Your local Honeywell Home and Building Control Sales Office (check white pages of your phone directory).
2. Home and Building Control Customer Satisfaction
Honeywell Inc., 1885 Douglas Drive North
Minneapolis, Minnesota 55422-4386 (612) 951-1000
In Canada—Honeywell Limited/Honeywell Limitee, 740 Ellesmere Road, Scarborough, Ontario M1P 2V9 International Sales and
Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico,
Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
5
.
TABLE 1—TERMINAL RATINGS.
1
1
Power Dissipation:
RM7800: 10W maximum.
Display Module: 3W maximum.
Maximum Total Connected Load: 2000 VA.
Fusing: Total Connected Load: 20A maximum, type
FRN or equivalent.
Ratings
120 Vac, 1A pilot duty.
120 Vac (+10/-15%), 50 or 60 Hz (+/- 10%).
120 Vac, 9.8AFL, 58.8ALR (inrush).
120 Vac, 1 mA.
120 Vac, 9A.
120 Vac, 4.5A ignition and 50VA pilot duty.
120 Vac, 2A pilot duty.
120 Vac, 4.5A Ignition.
60 to 220 Vac, current limited.
120 Vac, 75 VA pilot duty.
120 Vac, 75 VA pilot duty.
120 Vac, 75 VA pilot duty.
120 Vac, 75 VA pilot duty.
120 Vac, 1 mA.
120 Vac, 1 mA.
120 Vac, 1 mA.
120 Vac, 2A pilot duty.
120 Vac, 0.5A.