Minimum Flow Adjustment For Hob Gas Taps - Baumatic PCG9110SS Instruction Manual

90cm single cavity gas cooking theatre
Table of Contents

Advertisement

* In reference conditions, gas temperature 15°C, atmospheric
pressure 1013.25 mbar
o Reassemble all the burners carefully; in particular you should
make sure that the flame spreader is correctly placed on the
burner.
o IMPORTANT: After changing the injectors YOU MUST
follow the minimum flow adjustment section below.

Minimum flow adjustment for hob gas taps.

All
work
registered engineer.
o Unscrew the adjusting screw, in order to increase the gas flow
or tighten the adjusting screw to decrease the gas flow.
o The correct adjustment is obtained when the flame has a
length of about 3 – 4 mm.
o For butane/propane gas, the adjusting screw must be tightly
screwed in.
o Refit the control knob.
o Make sure that the flame does not go out by quickly turning
from maximum flow to minimum flow. If it does then remove
the control knob and make further adjustments to the gas
flow, testing it again once the adjustment has been made.
o IMPORTANT: On completion carry out a gas tightness
test.
must
be
carried
o Light the burner and set the knob
at the minimum position.
o Remove the knob from the tap and
place a small bladed screwdriver in
the centre of the tap shaft.
out
by
a
GASSAFE
29