Connecting the mains supply cable

o Open the mains terminal block cover as shown, unscrew the
cable clamp (A) and unscrew (not fully) the screws in the mains
terminal block (L, N, E) which secure the three wires of the
mains cable.
o Fit the cable and refit the cable clamp (A).
o Allow sufficient cable length for the cooker to be pulled out for
cleaning, but do not let it hang closer than 50mm to the floor.
o The cable can be looped if necessary, but make sure that is not
kinked or trapped when the cooker is in position.

Replacing the mains supply cable

If the mains supply cable is damaged, then it must be replaced by an
appropriate replacement.
The mains supply cable should be replaced in accordance with the
following instructions:
o Switch the appliance off at the socket.
o Open the box of the supply board.
o Unscrew the clamp (A) fixing the cable.
o Replace the cable with one of the same length and in accordance
with the specification given above.
o The "green-yellow" earth wire must be connected to the terminal
marked
. It must be about 10 mm longer than the live and
neutral wires.
IMPORTANT
The wires in the mains lead are
coloured in accordance with the
following code:
GREEN AND YELLOW
BLUE
BROWN
EARTH
NEUTRAL
LIVE