Gas adjustment (Conversion to LPG for the oven and grill)

All
registered engineer.
IMPORTANT: Always isolate the cooker from the electricity
supply before changing the injectors and/or adjusting the
minimum flow of the burners.
Burner
Gas Type
Type
LPG
Main
Oven
Natural
gas
LPG
Grill
Oven
Natural
gas
* In reference conditions, gas temperature 15°C, atmospheric
pressure 1013.25 mbar
IMPORTANT: You must change the oven and grill injectors.
work
must
Pressure Injector
G30/
28...
G31
30/37
G20
20
G30/
28...
G31
30/37
G20
20
be
carried
out
o Free the burners from their
fixing screws.
o Unscrew the injectors and replace
them with the stipulated injector
for the new gas supply (see table
below).
Gas
Marking
consumption*
(1/100
mm)
98
305 g/h
150
400 dm³/h
88
240 g/h
136
314 dm³/h
by
a
GASSAFE
MAX
MIN
Power
Power
(kW)
(kW)
4.200
1.000
3.300
N/A
30