Honeywell BENDIX KING KT 73 Installation Manual page 70

Mode s transponder
Hide thumbs Also See for BENDIX KING KT 73:
Table of Contents

Advertisement

Preliminary - Subject To Change Without Notice
BENDIX/KING
TEST
Mode S
Reply Jitter
ATCRBS
SLS Level
ATCRBS Reply
ATCRBS Only
All-Call
Mode S All-Call
Invalid Mode S
Address
Ident
Mode S UF 0
Mode S UF 4
Mode S UF 5
Mode S UF 11
Squitter
Rev 0, October/2002
DESCRIPTION
Measures transmitted pulse to pulse
time variations.
Checks sidelobe suppression function by
varying the SLS pulse level and monitoring
transponder reply rates.
Verifies transponder replies to Mode A and
C interrogations. Measures F1 to F2 spac-
ing and duration of pulses.
Verifies that the Mode S transponder does
not respond to Mode A only or Mode C
only interrogations.
Verifies that the transponder replies, with
the proper address, to a Mode S All-Call
interrogation.
Verifies that the transponder does not
reply to Mode S interrogations that
contain invalid addresses.
Verifies Ident function is operating.
Verifies that the transponder replies to a
Mode S UF 0 interrogation with the
correct altitude, address, and format.
Verifies that the transponder replies to a
Mode S UF 4 interrogation with the
correct altitude, address, and format.
Verifies that the transponder replies to a
Mode S UF 5 interrogation with the
correct ID, address, and format.
Verifies that the transponder replies to a
Mode S UF 11 interrogation with the
correct address, and format.
Verifies squitters are transmitted from the
transponder at varying intervals about a
one second rate.
TABLE 2-2 RAMP TESTS
(Sheet 2 of 2)
10563I00.JA
KT 73
PASS/FAIL
CRITERIA
0.05 µsec.
Reply if P1 exceeds P2 by
9 dB or more. No reply if
P2 equals or exceeds P1
Replies to interrogations.
F1 to F2 spacing, 20.3 µsec
±0.1 µsec. F1 and F2 pulse
width, 0.45 µsec ± 0.10
µsec.
No reply.
Proper reply address.
No reply.
Reply with SPI present in
ATCRBS Mode A only.
Reply with SPI absent.
Proper DF 0 reply.
Proper DF 4 reply.
Proper DF 5 reply.
Proper DF 11 reply.
1 second (0.8 to 2.4
seconds).
Page 2-54

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bendix king 066-01164-0101