Power Supply - Honeywell PS1202C Manual

Replacement power supply kits for electronic air cleaners
Table of Contents

Advertisement

Available languages

Available languages

PS1202C, PS2402C REPLACEMENT POWER SUPPLY KITS FOR ELECTRONIC AIR CLEANERS
TERMINAL STRIP
FRONT
1
2
TO
W8600E
3
WALL
PANEL
4
1 INTERLOCK SWITCH.
2 OUTPUT REDUCTION JUMPER.
3 AIRFLOW SWITCH DISABLE JUMPER.
4 ONE-CELL UNIT SIMILAR, BUT WITH JUST ONE CELL.
5 P1, P2 TERMINALS ON 120V MODELS ONLY. POWER CONNECTIONS ON 240V MODELS ARE TO
QUICK-CONNECTS ON POWER SUPPLY TRANSFORMER. BROWN LEAD GOES TO TOP TERMINAL
AND BLACK LEAD TO BOTTOM TERMINAL.
Fig. 10. Recent internal schematic for F52F Electronic Air cleaner with W8600E and AFS.
5
RPID BOARD
J1
1 2 3 4 5 6 7
P1
BLUE
B4
RED
R3
YELLOW
Y2
GREEN
G1
1 INTERLOCK SWITCH.
2 SHORTING BAR.
3 AIRFLOW SWITCH DISABLE JUMPER.
4 W8600E REMOTE PERFORMANCE INDICIATOR DRIVER.
5 NEON LIGHT.
Fig. 11. Retrofitted schematic for F52F Electronic Air Cleaner with W8600E and AFS.
69-1137EF—03
BLACK
BLACK
RPID BOARD
J2
1
2
3
4
5
6
J1
P1
1 2 3 4 5 6 7
BACK
1
2
3
4
BLACK
BLACK
J2
1
2
3
4
5
6
4
BLACK COLLECTOR
RED IONIZER

POWER SUPPLY

2
5
BLACK
1
BLACK
BLACK
BLACK COLLECTOR
RED IONIZER
POWER SUPPLY
2
BROWN
BLACK
ORANGE
GRAY
1
VIOLET
BLACK
BLACK
W4 W2 W1 W3
3
AIRFLOW SWITCH BOARD
8
RED
4
BLACK
GRAY
ORANGE
BROWN
VIOLET
BLACK
W4
W2
AIRFLOW SWITCH BOARD
RED
BLACK
BLACK
LINE VOLTAGE
CONTACT
BOARD
W1
W3
3
M33494A
CONTACT
BOARD
M33495A