Scan Result Notification - Casio DT-X200 Series Software Manual

Hide thumbs Also See for DT-X200 Series:
Table of Contents

Advertisement

Control character conversion example
The example of conversion after barcode data scanning is as shown below.
Control character conversion example
OBRDRV_R.ini
[ConvSrc]
Code01=0x1D
Code02=0x0A
[ConvDst]
Char01='/'
Char02='@'
[Delete]
Code01=0x02
Code02=0x03

Scan result notification

2.9.5
When scanning a barcode is complete, a notification about the scanning result is received by the
user via either LED, buzzer, or vibrator. Each notification method can be set to "Enable" or
"Disable".
Table 22-22
Configuration
LED
Disabled
Buzzer
Disabled
Vibrator
Disabled
*1 Scan failure
Scanning will fail when one of the following occurs.
 When a barcode with a number of digits outside the specified range is scanned
 When a check digit calculation error occurs
 Full ASCII conversion error occurs in scanning bar code of Code39 symbology or Code128
symbology.
The LED did not light for a scan failure.
Barcode data before conversion
01230x0A45670x1D890x0201
(Underlined portion is represents
the control character)
Scan
successful
Valid
On in green
None
Valid
Scanning
complete
sound
None
Valid
Vibrates
None
Barcode data after conversion
0123@4567/8901
- 0x0A is replaced by '@', and
0x1D by '/'.
- 0x02 is deleted.
Scan
Scanning
*1
Failure
interrupted
(Trigger key
released)
None
None
None
None
None
None
None
None
None
None
None
None
53
OBR buffer
Default
*2
overrun
On in green
Valid
None
Warning sound
Valid
None
None
Disabled
None

Advertisement