Your new unit is able to:
Flush easily, automatically, quickly and effectively components of air conditioning and refrigerant
circuits, evaporators, condensers, as well as the pipework.
Save money because SOLSTICE
flush – solvent vented to air).
Clean and flush a complete circuit without impacting the environment, thanks to closed circuit
operations: you and your shop will remain clean!

4. Accessories

4.1
Standard accessories – delivered together with the Unit
Hoses
1/4" SAE x 90cm with valve – blue
-
3/8" SAE x 90cm with valve – red
-
3/8" SAE x 180cm with valve – blue
-
3/8" SAE x 180cm with valve – red
-
Flare adapter 3/8" Male SAE x 1/4"
-
Fem. SAE
Additional external filter P48
-
4.2
Additional accessories to order
Please refer to your local supplier for the size of the cylinders of SOLSTICE
suits your flushing operation.

5. Technical Specifications

Voltage
Maximum power input
Compressor oil
Compressor oil filling
Connection to the flushed device
Connection to the refrigerant cylinder (liquid valve)
Connection to the refrigerant cylinder (vapor valve - nitrogen)
Maximum operating overpressure of the Unit
Ambient temperature
Weight without the refrigerant cylinder
Main dimensions (WxDxH)
Flushing agent for systems cleaning
The Flushing Unit EkoFlush-K572 is designed to operate exclusively with
the SOLSTICE
®
PF-C flushing agent can be re-used up to 20 times (+1 open
!! WARNING !!
®
PF-C flushing solvent produced by HONEYWELL.
- 4 -
1 piece
to connect the solvent cylinder, vapor outlet (Blue)
to the inlet on the rear side of the EkoFlush Unit
(Nitrogen)
1 piece
to connect the solvent cylinder, liquid outlet (Red),
to the inlet on the rear side of the EkoFlush Unit
(Liquid)
1 piece
to connect the EkoFlush front panel (OUT) to the
circuit to flush
1 piece
to connect the EkoFlush front panel (IN) to the
circuit to flush.
1 piece
Adapter for the vapor outlet valve on the solvent
cylinder (Blue)
1 piece
To intercept solid particles when flushing
particularly dirty circuits.
®
PF-C that best
110/230V, 50/60Hz
1850 W
ester oil ISO VG 46
0,4 kg
3/8" SAE
3/8" SAE
1/4" SAE
8 bar
+5° C – +40° C
54 kg
570x605x950 (mm)
®