Retrofill circuit breakers 800-5000a
Table of Contents

Advertisement

Document Conventions

Topics and text are divided into primary, secondary, and tertiary paragraph headings.

Related Publications

Publication
Brochure
Snapshot
Installation Manual AKD-10
Installation Manual AKD8
Installation Manual AKD6 (800A-2000A)
Installation Manual AKD5 (600A-2000A)
Installation Manual AKD-5/6 (3000A/3200A/4000A)
Accessory: Door Interlock (Door Interlock Kit)
Accessory Retrofill Doors Assembly
Accessory: Position Switch Plate & Position Switch Assembly & Wiring (Position Switch Kit)
Accessory: Neutral Rogowski CT Disconnect (Neutral Assemblies)
Accessory: Programmer Disconnects
Accessory: Finger Clusters (Cluster Assemblies)
Accessory: Secondary Disconnects
FAQ
Application Guide
Guideform Spec
Spare/Renewal Parts Guide
Neutral CT Adapters

Service and Support

Service and support always available from GE Energy.

Estimated Time to Complete Tasks

Verify the secondary disconnects and match the switchgear cublicle which may take up to 1Hr depending on
the complexity of the original breaker. Once the retrofill breaker is fully prepared, it should take about 20
minutes to swap out the old breaker and rack in the new EntelliGuard R retrofill circuit breaker if the proper
lifting bar and hoist are available, it may take an additional 30 Min to replace the Door.
The EntelliGuard R retrofill, when ordered with 4 wire ground fault, will be equipped with a Neutral CT
adapter. The adapter will modify the GE MicroVersaTrip type Neutral CT output to a Rogowski sensor output
compatible with the EntelliGuard R's Trip Unit. With this device, it will not be necessary to change the neutral
CT in the switchgear to a Rogowski sensor.

Product Specs

Weight (lbs.)

Retrofill Breaker
WPS-08, WPH-08
WPX-08, WPS-16 WPH-16, WPS-20
WPS-32, WPH-32 WPX-32
WPS-40, WPX-40
WPS-50, WPX-50
EntelliGuard R Circuit Breaker Retrofill AKD-10 Installation Manual
6
Weight
Box Wt. 10101655P1
230
11
270
11
600
15
625
15
700
15
Publication Number
DEA-532
DEE-543
DEH-41550
DEH-41549
DEH-41548
DEH-41547
DEH0005240
DEH-41529
DEH-41563
DEH-41530
DEH-41531
DEH-41532
DEH-41533
DEH-41534
DEQ-171
DET-753
DET-754
DET-755
DEH0002400
Pallet 10101650P1 Wt.
Accessories Wt.
24
24
30
30
38
DEH41550 R06
Total Weight
2
267
2
307
2
647
2
672
2
759