Fault Code F13: Water Intake Fault At End Of Step - Miele G 1 Series Technical Information

Hide thumbs Also See for G 1 Series:
Table of Contents

Advertisement

G 1xxx/G 2xxx
5. Remove the filter with needlenose pliers.
6. Clean or replace the filter as necessary. See Section 050-4.1.
Cause:
Water inlet valve defective.
Remedy:
Check the water inlet valve for proper operation by performing the following
steps:
1. Ensure that the water supply is open and that there is access to the valve
housing.
2. Select and start a wash program.
3. After the drain step (30 seconds), the water inlet step will begin. Wrap
your hand around the valve housing. If you feel a mild vibration, then the
valve is receiving power. Replace the WPS valve (Section 050-4.2). If not,
then go to the next step.
4. Remove the drip pan and check the electrical connector to the inlet valves
(mounted on the left toekick) for power. If power is present, then check
the connectors and wiring. If not, then go to the next step.
5. Check for power coming off of the electronic board. If no power, then
replace the electronic board. If power is present, check wiring from
electronic board to electrical connector. Replace and repair as necessary.
3.15

Fault Code F13: Water Intake Fault at End of Step

Symptom:
The program is interrupted and the drain pump is operated. After
approximately 2 to 4 minutes, the buzzer is activated for 2 minutes.
See Table 080-3 for model-specific fault indications.
Background information:
This fault is registered when the desired number of pulses, which varies
depending on program, has not been detected within a certain given time
(maximum 4 minutes).
If the selected program starts with a water softener flushing cycle, the fault
code register check is carried out earlier. In the event of a fault, the selected
program is interrupted after approximately 30 seconds and the fault is
indicated.
Cause:
On-site water supply not in order (water pressure below 14.5 pounds per
square inch).
Remedy:
The on-site water supply should be checked by a specialist.
Cause:
Water inlet valve defective.
Remedy:
Check the water inlet valve and replace it if necessary (Section 050-4.2).