Makita DHR182 Instruction Manual page 18

Cordless combination hammer
Hide thumbs Also See for DHR182:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Hammer drilling operation
CAUTION:
There is tremendous and sudden
twisting force exerted on the tool/drill bit at the time of
hole break-through, when the hole becomes clogged
with chips and particles, or when striking reinforcing
rods embedded in the concrete. Always use the side
grip (auxiliary handle) and firmly hold the tool by
both side grip and switch handle during opera-
tions. Failure to do so may result in the loss of control
of the tool and potentially severe injury.
Set the action mode changing knob to the
Position the drill bit at the desired location for the hole,
then pull the switch trigger. Do not force the tool. Light
pressure gives best results. Keep the tool in position
and prevent it from slipping away from the hole.
Do not apply more pressure when the hole becomes
clogged with chips or particles. Instead, run the tool at
an idle, then remove the drill bit partially from the hole.
By repeating this several times, the hole will be cleaned
out and normal drilling may be resumed.
NOTE: Eccentricity in the drill bit rotation may occur
while operating the tool with no load. The tool auto-
matically centers itself during operation. This does not
affect the drilling precision.
Chipping/Scaling/Demolition
Set the action mode changing knob to the
Hold the tool firmly with both hands. Turn the tool on
and apply slight pressure on the tool so that the tool will
not bounce around, uncontrolled.
Pressing very hard on the tool will not increase the
efficiency.
► Fig.34
Drilling in wood or metal
CAUTION:
Hold the tool firmly and exert care
when the drill bit begins to break through the
workpiece. There is a tremendous force exerted on
the tool/drill bit at the time of hole break through.
CAUTION:
A stuck drill bit can be removed
simply by setting the reversing switch to reverse
rotation in order to back out. However, the tool
may back out abruptly if you do not hold it firmly.
CAUTION:
Always secure workpieces in a
vise or similar hold-down device.
NOTICE:
Never use "rotation with hammering"
when the drill chuck is installed on the tool. The
drill chuck may be damaged.
Also, the drill chuck will come off when reversing the tool.
NOTICE:
Pressing excessively on the tool will
not speed up the drilling. In fact, this excessive
pressure will only serve to damage the tip of your drill
bit, decrease the tool performance and shorten the
service life of the tool.
Set the action mode changing knob to the
Attach the chuck adapter to a keyless drill chuck to
which 1/2"-20 size screw can be installed, and then
install them to the tool. When installing it, refer to the
section "Installing or removing drill bit".
► Fig.35: 1. Drill chuck assembly 2. Chuck adapter
Diamond core drilling
NOTICE:
operations using "rotation with hammering"
action, the diamond core bit may be damaged.
When performing diamond core drilling operations,
always set the change lever to the
"rotation only" action.
symbol.
Beating dust on the filter
Optional accessory
CAUTION:
case while the dust case is removed from the
dust collection system. Doing so may cause dust
inhalation.
CAUTION:
turning the dial on the dust case. Turning the dial
while the tool is running may result in the loss of
control of the tool.
By beating the dust on the filter inside the dust case,
you can keep the vacuum efficiency and also reduce
the number of times to dispose of the dust.
Turn the dial on the dust case three times after col-
symbol.
lecting every 50,000 mm
vacuum performance declined.
NOTE: 50,000 mm
holes of ø10 mm and 65 mm depth (14 holes of ø3/8"
and 2" depth).
► Fig.36: 1. Dust case 2. Dial
Disposing of dust
Optional accessory
CAUTION:
switched off and the battery cartridge is removed
before carrying out any work on the tool.
CAUTION:
disposing of dust.
CAUTION:
before the dust case becomes full. Failure to do so
may decrease the dust collection performance and
cause dust inhalation.
CAUTION:
decreases if the filter in the dust case become
clogged. Replace the filter with new one after
approximately 200 times of dust fulfillment as a
guide. Failure to do so may cause dust inhalation.
1.
Remove the dust case while pressing down the
lever of the dust case.
► Fig.37: 1. Lever
2.
Open the cover of the dust case.
symbol.
► Fig.38: 1. Cover
18 ENGLISH
If performing diamond core drilling
Do not turn the dial on the dust
Always switch off the tool when
3
of dust or when you feel the
3
of dust equivalents to drilling 10
Always be sure that the tool is
Be sure to wear dust mask when
Empty the dust case regularly
The performance of dust collection
position to use

Advertisement

Table of Contents
loading

Table of Contents