Samsung OfficeServ 7400 Technical Manual
Hide thumbs Also See for OfficeServ 7400:

Advertisement

OfficeServ 7400
TECHNICAL MANUAL
T A B L E
I N S TA L L AT I O N S E C T I O N
PART
DESCRIPTION
1
PRE-INSTALLATION INFORMATION
1.1
1.2
1.3
1.4
2
INSTALLING CABINETS
2.1
2.2
2.3
2.4
3
INSTALLING AND REPLACING BOARDS
3.1
3.2
3.3
3.4
4
CONNECTING EXTERNAL BATTERIES
4.1
5
CONNECTING POWER
5.1
5.2
5.3
O F
SITE REQUIREMENTS ............................................................... 1.1
GROUNDING CONDITIONS ....................................................... 1.2
POWER CONDITIONS ................................................................ 1.4
UNPACKING AND INSPECTION ................................................ 1.4
SYSTEM INSTALLATION PROCEDURE ..................................... 2.1
SELECTING INSTALLATION METHOD ...................................... 2.1
INSTALLING IN A RACK ............................................................. 2.1
CONNECTING GROUND WIRES ............................................... 2.5
CABINET CONFIGURATION....................................................... 3.1
MCP40 AND LCP40 MODULES.................................................. 3.5
INTERFACE BOARDS ............................................................... 3.15
CONNECTING POWER FAIL TRANSFER................................. 3.51
CONNECTING EXTERNAL BATTERIES ..................................... 4.1
BEFORE CONNECTING POWER ............................................... 5.1
PROCEDURE FOR CONNECTING POWER ............................... 5.1
CONNECTING THE OFFICESERV 7150 EXTERNAL PoE
PSU SUPPLEMENTAL POWER SUPPLY .................................... 5.2
Home Page
TABLE OF CONTENTS JUNE 2006
C O N T E N T S
Table of Contents
INSTALLATION
PAGE

Advertisement

Table of Contents
loading

Summary of Contents for Samsung OfficeServ 7400

  • Page 1 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL TABLE OF CONTENTS JUNE 2006 T A B L E C O N T E N T S I N S TA L L AT I O N S E C T I O N...
  • Page 2: Table Of Contents

    Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL TABLE OF CONTENTS JUNE 2006 CONNECTING C.O. LINES SAFETY PRECAUTIONS ............. 6.1 CONNECTING C.O. LINES ............6.2 CONNECTING STATIONS AND ADDITIONAL EQUIPMENT CONNECTING STATIONS ............7.1 CONNECTING ADDITIONAL EQUIPMENT ......7.23 POWER UP PROCEDURES PRE-CHECK ................
  • Page 3 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL TABLE OF CONTENTS MAY 2006 FIGURE 3.4: Switch Settings FIGURE 3.5: Installing the Processor Board (1) FIGURE 3.6: Installing the Processor Board (2) FIGURE 3.7: LP40 Link Cable FIGURE 3.8: Connecting the MP40 Board to LP40 Board FIGURE 3.9: Connecting MP40 to OS7200 LCP...
  • Page 4 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL TABLE OF CONTENTS JUNE 2006 FIGURE 3.34: Front View of the PLIM Board FIGURE 3.35: Setting the jumpers on the GPLIM Module FIGURE 3.36: Front View of the GPLIM Module FIGURE 3.37: Setting the jumpers on the GSIM Module...
  • Page 5 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL TABLE OF CONTENTS JUNE 2006 FIGURE 7.2: RJ-45 Port of the 16SLI2 Board FIGURE 7.3: RJ-45 Port of the 8COMBO Board (For Analog Phone) FIGURE 7.4: RJ-45 Port of the 8DLI Board (For Digital Phone) FIGURE 7.5: RJ-45 Port of the 16DLI2 Board (For Digital Phone)
  • Page 6 TABLE 5.2: Input Voltage and Frequency TABLE 5.3: Rated Output in the Case of Operation with AC TABLE 5.4: Rated Output in the Case of Operation with DC TABLE 6.1: OfficeServ 7400 Line Conditions TABLE 7.1: Distance Between Stations and the System...
  • Page 7 • Do not install in close proximity to a fire sprinkler or other sources of water. • A dedicated commercial AC power outlet is required. Do not use extension cords. • Ensure that all wires and cables to and from the OfficeServ 7400 do not cross fluorescent lights or run in parallel with AC wires.
  • Page 8 The OfficeServ 7400 system requires that a supplementary earth ground be connected to the system. This is the preferred method of grounding the OfficeServ 7400. It should be noted that when the third wire ground becomes inferior it many prevent the digital data bus from canceling out noise.
  • Page 9 Obviously, it is important to have a good source of ground connected to the OfficeServ 7400 system to drain this energy off. Again, a good earth ground source is required by the OfficeServ 7400 system.
  • Page 10: Table 1.1 Power Specifications

    582.3W consumption/PSU 1.4 UNPACKING AND INSPECTION The OfficeServ 7400 can be configured as a single cabinet, dual cabinet, or 3 cabinet system. All OfficeServ 7400 cabinets are identical when shipped from Samsung. After unpacking the cabinet(s), inspect for signs of physical damage. If any damage is detected, do not attempt to install the system.
  • Page 11 2.1 SYSTEM INSTALLATION PROCEDURE Installation Overview: 1) Install the OfficeServ 7400 cabinet on a table or inside a data rack depending on the installation environment. 2) Connect the ground to the ground lug behind the main cabinet.
  • Page 12 Figure 2.1 Tools Required for Rack Installation 2.3.3 Installing in a Rack The procedure for installing the OfficeServ 7400 cabinet inside a 19-inch rack is as follows: 1) Attach the cabinet bracket to the bottom surface of the OfficeServ 7400 cabinet and fasten the bracket firmly with the three screws.
  • Page 13 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 2 JUNE 2006 2) Attach the rack brackets to both sides of the rack and fasten the brackets firmly with the six screws. Figure 2.3 Rack Installation (2) 3) Align the cabinet to the guide rails of the rack and slide the cabinet into the rack.
  • Page 14 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 2 JUNE 2006 4) Align the two holes of the cabinet bracket and the holes of the rack brackets and fasten the cabinet to the rack with the two screws.
  • Page 15 As shown in the figure below, connect an earth ground to the ground lug behind the OfficeServ 7400. For an expansion cabinet, connect and ground the external ground wire between the expansion cabinet and the main cabinet.
  • Page 16 PART 3 JUNE 2006 PART 3. INSTALLING AND REPLACING BOARDS This section describes how to install and replace various boards of the OfficeServ 7400 system. 3.1 CABINET CONFIGURATION The main and expansion cabinets of the OfficeServ 7400 system have 12 slots each.
  • Page 17 The OfficeServ 7200 cabinet can be used as expansion cabinet 1 and/or expansion cabinet 2 for the OfficeServ 7400 system. Simply install an OS7200 LCP card in slot 0 of the cabinet and connect it to the MP40 via LCP link cable. The OS7200 cabinet cannot be used as a MAIN cabinet for a OS7400 system.
  • Page 18: Table 3.1 Cards/Slot Compatibility Rules

    Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 3 JUNE 2006 Figure 3.2 Possible Combination of OS7200 and OS7400 The following table outlines the rules for card/slot compatibility and configuration. Table 3.1 Cards/Slot Compatibility Rules Chassis Slot...
  • Page 19 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 3 JUNE 2006 IMPORTANT: • The OS7200 MCP, 4WLI and WIM module are NOT allowed in an OS7400 system • Although the MGI64 and TEPRI2 can be installed in any universal slot of the OS7400 expansion cabinet, it is recommended that they be installed in the MAIN cabinet in order to utilize the full capacity of the cards.
  • Page 20 MP40 and LP40 boards. The OfficeServ 7400 MP40 (Main Control Processor) controls the system operation. The MP40 is required for all configurations and goes in slot 3 of the main cabinet. The LP40 goes in slot 0 of the MAIN cabinet and each OS7400 expansion cabinet.
  • Page 21 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 3 JUNE 2006 • The system database is NOT stored in SRAM. The system database is now stored in the on-board NAND FLASH. This data can remain in NAND-FLASH until the system is defaulted.
  • Page 22: Table 3.2 Types Of Control Boards

    The procedure for installing the MP40 board and the LP40 board to each slot is as follows: 1) Check the exterior of the MP40 board and the LP40 board for any damage. If damage is found, do not proceed with installation. Contact Samsung Technical Support. Power the system OFF when installing or removing boards.
  • Page 23 4) The above steps 2~3 also apply to installing the LP40 board to slot 0 each cabinet. 3.2.3 Connecting MP40 Board to LP40 Board If the OfficeServ 7400 system consists of a Main Cabinet and up to two expansion cabinets. Connect the MP40 board to each LP40 board located in the expansion cabinets using link cables.
  • Page 24 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 3 JUNE 2006 LINK31, LINK32, and LINK33 to LP40 ports LINK1, LINK2, and LINK3 in the expansion cabinet 3. LP40 LINK1 LINK3 MISC1 LINK2 MISC2 LINK31 LINK32 LINK23 MP40 Figure 3.8 Connecting MP40 Board to LP40 Board...
  • Page 25: Table 3.3 Ports And Leds Of The Mp40 Board

    Port for installing the 32MB Smart Media card. This card contains the main system software. Port for establishing the 10 Base-T/100 Base-Tx Ethernet connection. Serial port (Samsung Engineering Use ONLY). Button for resetting the MP40 board. RUN LED This LED indicates the status of the MP40.
  • Page 26 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 3 JUNE 2006 Ports & LEDs Function Description LAN LED Status of LAN operation - Off: No-power and no-connection of LAN port - On: The color of the LED shows the LAN transmission speed and connection speed.
  • Page 27 Function Description Connection for OfficeServ 7150 PoE power supply Alarm port Port for connecting 10/100 BASE-T LAN (reserved for future use) For internal Samsung engineering use only Button for resetting LP40 module RUN LED Indicates the status of the LP40.
  • Page 28 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 3 JUNE 2006 3.2.6 Optional Daughter Boards There are 5 types of optional daughter cards that can be installed ONLY on the LP40. Each optional daughtercard must be installed in specific positions of the LP40...
  • Page 29: Table 3.5 Position For Optional Daughter Cards

    Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 3 JUNE 2006 o Each SCM provides 12 additional conference circuits (5 parties ea.) o You can install 2 SCM’s per LP40, however, you can only 12 conference circuits from ONE of them. This means (6+12) 18 Maximum conference circuits per LP40.
  • Page 30 Interface boards can be installed in any universal slot according to the rules outlined in table 3.1. Universal slots are slots 1, 2, and 4~11 in the MAIN cabinet and slots 1~11 in the OfficeServ 7400 expansion cabinets. For OS7200 expansion cabinets, universal slots are slots 1~5.
  • Page 31 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 3 JUNE 2006 Figure 3.14 Installing Interface Board into Slot 2) Push the front panel lever of the interface board until the board is completely inserted into the slot.
  • Page 32 TECHNICAL MANUAL PART 3 JUNE 2006 3.3.2 Replacing Boards If the OfficeServ 7400 system fails to operate normally due to an error on the power supply board, control board, or interface board, replace the board with a new one. Removing Cables Replace a board after removing all cables connected to the board.
  • Page 33 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 3 JUNE 2006 is not limit to how many TEPRI/TEPRIa cards you can add to the system. NOTE: Do not insert this card with system power ON. TEPRI Card Dip Switch Switch No.
  • Page 34 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 3 JUNE 2006 Figure 3.16 Setting switches and jumpers on the TEPRI Board JUMPER SETTING The TEPRI board comes from the factory with the following jumper settings. These settings should NOT be changed.
  • Page 35 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 3 JUNE 2006 T1/E1 24B + D User (Slave) Network (Master) Figure 3.17 Setting switches and Jumpers on the TEPRIa Board FRONT VIEW OF TEPRI BOARD The front view of the TEPRI board is shown in the picture below.
  • Page 36: Table 3.6 Ports And Leds Of The Tepri

    Table 3.6 Ports and LEDs of the TEPRI Ports & LEDs Function Description T1/E1/PRI Ports that connect the T1/E1/PRI cable. Serial port (for Samsung Use ONLY) Button for resetting the TEPRI/TEPRIa board. SYNC LED Clock synchronization. - On: Indicates loss of framing (Error Condition).
  • Page 37: Table 3.7 Front Panel Components Of The Tepria

    Function Description Port for connecting T1/E1/PRI cables Port for connecting to Ethernet (reserved for future use) Serial port for internal Samsung engineering use only. TP1 LED Indicates the type of the circuit connected to port P1 - On: PRI in operation...
  • Page 38 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 3 JUNE 2006 TEPRI2 CARD The TEPRI2 card is a DUAL circuit digital trunk interface that supports either T1 or ISDN PRI service. It also supports Q-Sig/PRI signaling required for networking multiple systems.
  • Page 39 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 3 JUNE 2006 JUMPER SETTING • S2, dip switch #1 should be set to ON. This setting sets the entire TEPRI2 card into T1 mode. • S2, dip switches 2~4 are used for configuring the first circuit P1 •...
  • Page 40: Table 3.9 Ports And Leds Of The 8Trk

    Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 3 JUNE 2006 3.3.4 8TRK The 8TRK board provides 8 ports for analog trunk lines with Caller ID capabilities. This board can go into any universal slot in any cabinet. Add as many as needed.
  • Page 41: Table 3.10 Ports Of The 16Sli2

    Refer to Section 7.1.3 (Connecting a Digital Phone) for port Pinout and Wiring. 3.3.6 8DLI BOARD This board provides 8 ports for connecting Samsung Digital Keysets. This board can go into any universal slot of any cabinet. Add as many as needed.
  • Page 42: Table 3.11 Ports And Leds Of The 8Dli Board

    Table 3.11 Ports and LEDs of the 8DLI Board Ports Function Description P1~P8 Station ports of Samsung Digital Phones. P1~P8 LED These LEDs indicate the status of the ports. -Off: The station is not being used. -On: The station is being used.
  • Page 43 3.3.7 8COMBO This board provides 8 ports for connecting analog stations and 8 ports for connecting Samsung Digital Keysets. This board can go into any universal slot of any cabinet. Add as many as needed. FRONT VIEW OF 8COMBO BOARD The front view of the 8COMBO board is shown in the picture below.
  • Page 44: Table 3.12 16Sli2 Board Ports

    Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 3 JUNE 2006 3.3.8 16SLI2/16MWSLI This board provides 16 ports for connecting analog stations. It can go into any universal slot of any cabinet. Add as many as needed. This card automatically detects DTMF or dial pulse signals from the SLT.
  • Page 45: Table 3.13 Ports And Leds Of The 8Sli

    Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 3 JUNE 2006 3.3.9 8SLI This board provides 8 ports for connecting analog stations. It can go into universal slot of any cabinet. Add as many as needed. This card automatically detects DTMF or dial pulse signals from SLT.
  • Page 46 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 3 JUNE 2006 GWIM Module 3.3.10 Gigabit WAN Interface Module(GWIM) is a data router module allowing communication between the WAN and LAN. The GWIM can go into any universal slot in any OS7400 cabinet.
  • Page 47: Table 3.14 Ports And Leds Of The Gwim Module

    Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 3 JUNE 2006 2) Align the connector of the optional security daughter card (GWIMS) to that of the GWIM connector and firmly press the optional module downward. GWIMS Figure 3.29 Mounting an Optional Securing Daughter Card on the GWIM Module FRONT VIEW OF GWIM MODULE Figure 3.30 Front Panel View of the GWIM Module...
  • Page 48 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 3 JUNE 2006 Port, LED Function Description RUN LED The status of the GWIM - Off: No power supplied or the operation in abnormal status - LED turns Green: Normal status V.35 LED...
  • Page 49 Ethernet (IEEE 802.3af). This means that it can provide power to any IEEE 802.3af compliant device that is connected to any of its Ethernet ports. All Samsung ITP phones and SMT-R2000 Dual-Band AP’s can receive power when connected to the PLIM.
  • Page 50 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 3 JUNE 2006 provides up to 6600mA of output current. PER EACH OS7400 CABINET (not per system), the SUM of all current drawn from 1) devices powered by PLIM cards, 2) digital key sets connected to DLI ports 3) analog devices connected to SLI ports 4) devices powered by the GPLIM’s 5)the GWIM, GSIM and GPLIM cards...
  • Page 51: Table 3.15 Ports And Leds Of The Plim

    This module provides 12-10/100 BASE-T interface port and 2- 1000 BASE-TX/SX/LX ports. The GPLIM can provide power to any IEEE 802.3af compliant device that is connected its Ethernet ports. All Samsung ITP phones and SMT-R2000 Dual-Band AP’s can receive power when connected to the GPLIM. When 3.36...
  • Page 52 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 3 JUNE 2006 connected to the GPLIM Ethernet port, these devices no longer need the AC power adapter. SPECIFICATIONS • The GPLIM can be installed in any universal slot of any OS7400 cabinet.
  • Page 53: Table 3.16 Ports And Leds Of Gplim

    Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 3 JUNE 2006 Set jumpers J1~J4 in the GPLIM module. Figure 3.35 Setting the jumpers of the GPLIM module FRONT VIEW OF GPLIM MODULE Figure 3.36 Front View of the GPLIM module Table 3.16 Ports and LEDs of GPLIM...
  • Page 54 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 3 JUNE 2006 Ports, LED Function Description Left LEDs of P1~P6 First LED: Link operation of P1~P6 - On: LED turns green when a link is in operation - Blink: Each port blinks on active status...
  • Page 55 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 3 JUNE 2006 Figure 3.37 Setting the Jumpers of the GSIM Module FRONT VIEW OF GSIM MODULE Figure 3.38 Front View of GSIM Module Table 3.17 Ports and LEDs of GSIM...
  • Page 56 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 3 JUNE 2006 Port, LED Function Description LED blinks when P1~P10 are on active status 3.3.14 MGI (MEDIA GATEWAY INTERFACE) The MGI board provides a variety of Voice over IP (VoIP) services for the OfficeServ 7400.
  • Page 57: Table 3.18 Ports And Leds Of The Mgi

    Table 3.18 Ports and LEDs of the MGI Ports & LEDs Function Description Port that connects the Ethernet. Serial Port (for Samsung Use ONLY) Button for resetting the MGI. PWR LED This LED indicates the power supply status. - Off: Power is not being supplied.
  • Page 58: Table 3.19 Mgi64 Front Panel Components

    The MGI64 is a 64 channel Media gateway Interface card. Just like the MGI, The MGI64 board provides a variety of Voice over IP (VoIP) services for the OfficeServ 7400. This card is required for ITP phones, IP networking, IP trunking or any application that require VoIP.
  • Page 59 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 3 JUNE 2006 Ports & LEDs Function Description RUN LED This LED indicates MP40 status. - Off: Power is not being supplied. - On: Booting. - Blink: The RAM program is operating.
  • Page 60 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 3 JUNE 2006 SVMi-20E FRONT PANEL Figure 3.42 SVMi-20E LED Indications The Serial Interface: This can be used to connect a modem or PC to provide local or remote PC based administration. The connector is called the SIO connector.
  • Page 61 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 3 JUNE 2006 • LRT Status LED: This indicates that the LAN port is Receiving and/or Transmitting Data • SDN Status LED: This is the System Status LED showing the operating status of the card.
  • Page 62 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 3 JUNE 2006 Figure 3.43 SVMi-20E/HD with no optional boards installed (LEFT) and SVMi-20E/CF with all components installed (RIGHT) INSERTING THE CARD NOTE: Before powering off the KSU, it is recommended that you use MMC 740 and set MBX Download to 'No'.
  • Page 63 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 3 JUNE 2006 POWER UP PROCEDURE FOR SVMi-20E Follow the steps below to ensure that the SVMi-20E is properly setup. POWER UP 1. Complete insertion of the SVMi-20E and all other required interface cards and turn the system power switch ON.
  • Page 64 SVMi-20E hardware. You are now ready to begin programming the SVMi-20E Voice Mail/Auto Attendant system parameters. See the SAMSUNG SVMi-20E Programming Manual. NOTE: See MMC references in the SVMi-20E Programming Overview documentation for other MMCs that interact with the SVMi-20E.
  • Page 65 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 3 JUNE 2006 CORRECT SYSTEM SHUTDOWN Whenever possible one of the following procedures should be followed when shutting down the SVMi-20E system and/or prior to shutting down the Telephone equipment.
  • Page 66 1 on the 8SLI, 16SLI2, or 16MWSLI cards. In case the OfficeServ 7400 loses power from its AC source, and no battery backup is available, this feature is automatically activated. The analog telephone connected to Port 1 of the SLI will get C.O.
  • Page 67 OfficeServ 7400 to emergency backup batteries. The OfficeServ 7400 can also run without AC power on a -48VDC battery system or rectifier. There should be no more than a 0.5VDC drop in voltage from the OfficeServ 7400 and the batteries.
  • Page 68 2) Connect the red line(GND) of the battery cable to the(+) terminal, and the blue line (-48 VDC) to the(-) terminal of the battery. Then, connect the other end of the battery cable to the external battery socket on the rear panel of the OfficeServ 7400 cabinet.
  • Page 69 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 4 JUNE 2006 Connect Battery only to the BATTERY Conector socket on the back panel of the OS7400. DO NOT CONNECT BATTERY TO THE POE INPUT CONNECTOR. Figure 4.2 Connecting an External Battery (2)
  • Page 70 5.2 PROCEDURE FOR CONNECTING POWER SINGLE CABINET CONFIGURATION Use the AC power cable provided with the OfficeServ 7400 system to connect the input power terminal on the rear panel of the cabinet to a grounded outlet. Figure 5.1 Connecting Power (for Single Cabinet)
  • Page 71 A two-module system (7150 with 2 PoE-M PSU module) provides -54V, 15 A. The GPLIM and PLIM module uses the -48V rail from the OfficeServ 7400 power supply to provide power to the connected devices over ethernet. The OfficeServ 7400 power supply provides up to 6600mA of output current.
  • Page 72: Table 5.1 Consumption Per Device

    Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 5 JUNE 2006 Device Current Comsumption CARD Name Type for Each Device (mA) 16DLI2 2-Line LCD Keyset Analog Phone 16SLI2 16MWSLI MW Phone PLIM or GPLIM ITP-5021D, ITP-5107S, ITP-5121D...
  • Page 73 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 5 JUNE 2006 Grounding Requirements • Follow all grounding conditions listed in section 1.2. • The grounding wire of OfficeServ 7150 PoE PSU should not be connected to the conduit of the power cables in the building.
  • Page 74 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 5 JUNE 2006 OFFICESERV 7150 FRONT VIEW Front view of the OfficeServ 7150 cabinet is as shown in the following illustration. The cabinet consists of two slots and one distributor. A POE-M PSU module is inserted to each slot.
  • Page 75 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 5 JUNE 2006 The POE-M PSU modules are sold separately. Extra PoE cables can be purchased if needed. OFFICESERV 7150 INSTALLATION Electric Shock Make sure to turn this product OFF. Handling this product with AC power ON may cause electric shock.
  • Page 76 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 5 JUNE 2006 GROUNDING CONDITIONS Observe the following requirements when OfficeServ 7150 PoE is grounded. • The grounding wire of OfficeServ 7150 PoE shall be connected to the ground through a qualified grounding media.
  • Page 77 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 5 JUNE 2006 INSTALLATION PROCEDURE This section describes how to install OfficeServ 7150 PoE on the floor or inside a rack. Select an Installation Method OfficeServ 7150 may be installed either on the floor or inside a 19 inch rack.
  • Page 78 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 5 JUNE 2006 Figure 5.5 Tools Needed for Installation in a Rack 1) Attach the cross bar bracket bracket to the bottom of OfficeServ 7150 PoE, and tighten with three screws.
  • Page 79 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 5 JUNE 2006 2) Attach the rack mount brackets to both sides of the rack, and tighten with six screws. Figure 5.7 Installation in a Rack (2) 3) Guide the OS7150 unit through the guide rails formed by the rack mount brackets.
  • Page 80 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 5 JUNE 2006 4) Match the cross bar bracket attached to the 7150 to the two holes in the bracket inside the rack properly and then tighten with screws.
  • Page 81 • Disconnect and turn off all power to the 7150 before connecting the battery. • Disconnect any connections to an OfficeServ 7400 system. • Pay attention to polarity (+,-) orientation of the battery when connecting to the system. 1) A battery cable comes with the OfficeServ 7150 cabinet. One end of the battery cable is a green keyed plastic connector.
  • Page 82 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 5 JUNE 2006 Figure 5.11 Connecting an External Battery Safety Tips in Connecting External Battery Cable As OfficeServ 7150 is a high output power supply system, maximum of DC48V 30A may be flown from the battery.
  • Page 83 Blue wire to the first -54V lug from the left on the back of the 7150. 4) If connection to a second OfficeServ 7400 cabinet is required, then repeat the steps above and connect the red wire to the 2 GND lug from the left and the blue wire to the second +54V lug from the left.
  • Page 84: Table 5.2 Input Voltage And Frequency

    Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 5 JUNE 2006 OfficeServ 7150 Red Line Blue Line Socket for External Battery OfficeServ 7400 Figure 5.14 Connecting OS 7150 to OS 7400 SPECIFICATIONS OF OFFICESERV 7150 Specifications of Cabinet INPUT VOLTAGE &...
  • Page 85: Table 5.4 Rated Output In The Case Of Operation With Dc

    Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 5 JUNE 2006 RATED OUTPUT IN THE CASE OF OPERATION WITH DC Battery By-pass (DC 48V,48AH or lower), 7.5A 1 Module 2 Module Battery By-pass (DC 48V,48AH or lower), 15.0A Table 5.4 Rated Output in the Case of Operation with DC...
  • Page 86: Connecting C.o. Lines

    TECHNICAL MANUAL PART 6 JUNE 2006 PART 6. CONNECTING C.O. LINES This section describes how to connect C.O. lines to the OfficeServ 7400 system after installation. 6.1 SAFETY PRECAUTIONS To reduce the risk of personal injury, follow these precautions before connecting TELCO circuits: •...
  • Page 87 6.2.1 Connecting Common C.O. Lines Use a twisted pair of wires with AWG #24(or AWG #26) width to connect a common C.O. line to the terminal pin of a terminal box connected to the OfficeServ 7400 system equipped with an 8TRK board.
  • Page 88 Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 6 JUNE 2006 PARAMETER OPTIONS IN OFFICESERV 7400 Framing type Super Frame (SF) or D4 Extended Super Frame (ESF) Coding type AMI or B8ZS The coding type must be set up in the system to match the T1 span and is contained in MMC 808.
  • Page 89: Connecting Stations And Additional Equipment

    Analog phone Maximum 1 km/3280 ft (for AWG #24) Door phone Maximum 400 m/1312 ft (for AWG #24) Maximum 400 m/1312 ft (for AWG #24) NOTE: If you are connecting Samsung DCS keysets, the keyset version must be 1.2 or higher.
  • Page 90 7.1.2 Connecting an Analog Phone Connect an analog phone to the 8SLI, 16SLI2, 16MWSLI, 8COMBO board installed in the OfficeServ 7400 system. CONNECTING TO THE 8SLI BOARD Connect an analog phone to the 8SLI board by using a twisted pair of AWG #24 or AWG #26 wire.
  • Page 91 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 7 JUNE 2006 CONNECTING TO THE 8COMBO BOARD Connect an analog phone to the 8COMBO board by using a twisted pair of AWG #24 or AWG #26 wires. S1-S8 Port...
  • Page 92 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 7 JUNE 2006 CONNECTING TO 16DLI2 BOARD Connect a digital phone to the 16DLI2 board by using a twisted pair of AWG #24 or AWG #26 wires. P1-P16 Port (RJ-45) Pin No.
  • Page 93 Refer to the SMT-R200 AP documentation for wireless LAN installation information. 7.1.7 Connecting to a Door Phone and a Door Lock Connect a door phone and a door lock to the OfficeServ 7400 system by using a Door Phone Interface Module (DPIM).
  • Page 94 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 7 JUNE 2006 CONNECTING TO THE 8DLI BOARD P1~P8 (RJ-45) Pin No. Function DLI TIP DLI RING Figure 7.8 RJ-45 Port of 8DLI Board (For Door Phone) CONNECTING TO THE 16DLI2 BOARD...
  • Page 95 7.1.8 Connecting KDB-D/KDB-S KDB-D and KDB-S are modules installed on a digital phone connected to the OfficeServ 7400 system. The KDB module enhances the functions of the phone and increases the number of local ports according to module types. Caution for connecting KDB module KDB-D and KDB-S is only for a digital phone connected to the 8DLI board, not for a digital phone connected to a 16DLI2 board.
  • Page 96 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 7 JUNE 2006 iDCS KDB-DIGITAL LINE INTERFACE (FKDBD) This is a daughterboard that can be installed only in the 18 or 28 button keyset. The FKDBD will provide one additional DLI circuit for the connection of any digital station device such as a keyset, add-on module or DPIM.
  • Page 97 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 7 JUNE 2006 keyset aside. Attach the KDb-DLI to the keyset base with the four screws that are supplied (see Figure 7.13). Take care to ensure that the modular socket shows through the access hole in the base (see Figure 7.14).
  • Page 98 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 7 JUNE 2006 and plug the ribbon cable into the socket on the keyset PCB (see Figure 7.15) while making sure no damage occurs to the keyset PCB. Reattach the base to the keyset and test to ensure normal keyset operation.
  • Page 99 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 7 JUNE 2006 HOOK PLUG RIBBON CABLE FROM DAUGHTERBOARD INTO RIBBON CABLE CONNECTOR P7 Figure 7.15 Connecting Keyset Daugherboard to Keyset PCB RIBBON CABLE CONNECTOR MOUNTING SCREWS Figure 7.16 Installing KDB-SLI Daughterboard...
  • Page 100 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 7 JUNE 2006 LINE CORD SECOND KEYSET FIRST KEYSET Figure 7.17 Connecting a Keyset to a KDB-DLI LINE CORD SINGLE LINE TELEPHONE FIRST KEYSET Figure 7.18 Connecting a Single Line Telephone to a KDB-SLI...
  • Page 101 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 7 JUNE 2006 Figure 7.19 Connecting a Station Device to a KDB via MDF CONNECTING TO THE KDBS There are two methods for connecting devices to keyset daughterboards. The simplest method is to connect the second device directly by means of a line cord.
  • Page 102 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 7 JUNE 2006 HOLES FOR MOUNTING SCREWS NOTE: THE DIRECTORY CARD SLIDE TRAY IS NOT Figure 7.20 Wall-Mounting a Keyset WALL-MOUNTING KEYSETS iDCS keysets come equipped with a reversible base wedge. To wall-mount a keyset, remove the wedge from the keyset and remove the directory tray from the wedge.
  • Page 103 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 7 JUNE 2006 USED FOR ATTACHING AOM OR 64B MODULE WITH CONNECTOR CLIP HOLES FOR MOUNTING SCREWS NOTE: THE DIRECTORY CARD SLIDE TRAY IS NOT Figure 7.21 Ultra Base Wedge WALL-MOUNTING KEYSETS WITH ULTRA BASE WEDGE The keysets now come equipped with a new Ultra Base wedge.
  • Page 104 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 7 JUNE 2006 Use screw holes 1 and 3 to attach to a standard telephone wall-mount plate with locking pins. This method can cause the keyset to wobble as the keyset feet do not fit securely to the mounting surface.
  • Page 105 It must be assigned to that station in MMC 209. A maximum of four (4) 64 button modules can be programmed on a system. OfficeServ 7400 system can have a maximum of four (4) 64 button modules per keyset.
  • Page 106 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 7 JUNE 2006 Figure 7.24 Attaching 24B/12B to 64BM ATTACHING DCS 32 BUTTON AOM AND DCS 64B MODULES WITH MASTER STATION These new Ultra Base Wedges allow a connector clip (packaged with 64B Modules and AOMs) to be connected to the underside of the new style wedge and attach AOM(s) or 64B module(s) together with the main or “master”...
  • Page 107 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 7 JUNE 2006 Figure 7.25 Attaching 24B/12B to AOM ATTACHING iDCS 64 BUTTON MODULES TO AN iDCS KEYSET First remove the base wedge from the iDCS 64 Button Module and attach the bracket to it with two of the screws provided (see Figure 7.27).
  • Page 108 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 7 JUNE 2006 7B / SINGLE LINE ULTRA BASE WEDGE AOM ULTRA BASE WEDGE METAL CONNECTOR CLIP 7B/SINGLE LINE ULTRA BASE WEDGE 64BM ULTRA BASE WEDGE METAL CONNECTOR CLIP Figure 7.26 Attaching 7B/Single Line to AOM and 7B/Single Line to 64 BM...
  • Page 109 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 7 JUNE 2006 6) Place the support bracket over the ribbon cable and secure with the six screws provided. 7) Reattach the base pedestal. Figure 7.27 Attaching iDCS 64 Button Module to an iDCS Keyset...
  • Page 110 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 7 JUNE 2006 REMOVE KNOCKOUTS Figure 7.28 Attaching iDCS 14 Button Module to an iDCS Keyset ATTACHING DS 64 BUTTON MODULES TO a DS 5021D or a DS 5014D KEYSET First attach the bracket to the keyset with two of the screws provided.
  • Page 111: Connecting Additional Equipment

    MP40) 7.2.1 Connecting MOH/BGM Equipment The OfficeServ 7400 system offers music on hold. The system provides internal tone/music and external music sources per C.O. or extension lines as the music source. Two external music sources are offered. Connect the music sources to the MISCI port of the LP40 board.
  • Page 112 Instead of an internal speaker, external broadcasting equipment, such as amps or speakers, and additional equipment that can broadcast page(ring) signals outside a building can be connected to the OfficeServ 7400 system. Connect external/additional paging equipment to the MISC1 and MISC2 ports of the LP40 board.
  • Page 113 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 7 JUNE 2006 board. The power of the external/additional paging equipment should be connected separately. The MIS daughter board provides a voice pair and a two dry contact pairs to be used with customer-provided paging equipment.
  • Page 114 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 7 JUNE 2006 Dry Contact Dry Contact is a switch that can connect or cut the power or line to external equipment. 7.2.3 Loud Bell Interface When a station requires loud ringing, assign or pair that station to an audible ring tone output on the MIS daughter board using MMC 205.
  • Page 115 Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 7 JUNE 2006 Dry contact #1 (For common bell) MISC 2 Dry contact #2 (Page Relay) (For external broadcasting) Dry contact #3 MISC 1 (Page Relay) (For external broadcasting) Figure 7.32 Connecting Common Bell...
  • Page 116 PCs running 3 party applications (i.e. SMDR Reporting Packages, etc.). The OfficeServ 7400 can also print various reports to a LAN printer. Connect a LAN printer to a network segment that is routable to the MP40 LAN connection. OfficeServ 7400...
  • Page 117: Power Up Procedures

    10 % and 90 %. Take special caution since humidity affects the electrical components and connectors of the system. • Direct sunlight and dust: The room where the OfficeServ 7400 system is installed should be protected from direct sunlight and should have ventilation systems to prevent the system from malfunctioning due to dust.
  • Page 118: Checking The Fan

    Table of Contents Home Page OfficeServ 7400 INSTALLATION TECHNICAL MANUAL PART 8 JUNE 2006 Check the LEDs of the MP40 and LP40 boards. The RUN LED of the MP40 board lights green and the SM LED flashes when the system normally starts the booting process.
  • Page 119: Numbering Extensions And C.o. Lines

    According to the setting of the S2 switch (SW6, SW7, SW8) of the MP40 board, the OfficeServ 7400 system assigns 3 or 4 digits to C.O. lines, extensions, and extension groups. Refer to Section 4. Mounting and Replacing Boards of this manual for details on setting the S2 switch.
  • Page 120: Software And Database Management

    MANAGEMENT 9.1 SOFTWARE MANAGEMENT The OfficeServ 7400 operating software is stored on the SmartMedia card which is inserted into the front of the MP40 card. The SmartMedia card has 32 Megabytes of NAND flash memory and is formatted, with a custom format to allow faster loading, in a similar manner to a hard disk.
  • Page 121: Adding Boards To The System

    SYSTEM 10.1 ADDING STATIONS AND TRUNKS 1) Power the OfficeServ 7400 OFF before adding a new board. Locate a suitable empty card slot. Having located a suitable slot, insert the new card into the slot and push firmly in the middle of both card ejectors on the card to ensure that it is fully inserted into the back plane connector.