Install and Remove Small Form Pluggable Modules and Field Replaceable Units
Warning
Blank faceplates and cover panels serve three important functions: they reduce the risk of electric shock and
fire; they contain electromagnetic interference (EMI) that might disrupt other equipment; and they direct the
flow of cooling air through the chassis. Do not operate the system unless all cards, faceplates, front covers,
and rear covers are in place. Statement 1029

Remove and Replace SSD Storage

Before you begin
The M.2 storage module is a hardware that is 22mm wide and 80mm long. This hardware comes with different
storage capacities.
If you order M.2 storage module, the following are the steps to install it:
Procedure
Command or Action
Step 1
Remove the SSD panel from the bottom side of chassis by
unfastening the screws and keep the screws aside.