Issue 10.1
Program 50 : Common Channel Interoffice Signaling Service
Level:
IN
Description
Input Data
Item
No.
01
02
03
04
05
06
2 - 624
Use Program 50-02: Connecting System Settings to define the settings for
each CCIS Route ID.
CCIS Route ID
Item
Port Number of Common
Signaling Channel (T1)
Common Signaling
Channel Data Speed
Assignment (T1)
Originating Point Code
Destination Point Code
(T1)
Calling Name Indication
(T1)
Channel Number on the
CCH package
Assignment

50-02: Connecting System Settings

Route ID 1~8: CCIS via DTI
Route ID 9: CCIS via IAD/CD-PVAA (IP-CCIS)
Description
Specify the Trunk port to send D-
channel information. This program
is available for using DTI package.
Assign the baud rate of Common
Signaling Channel on DTI
package.
Assign the Point Code of own side.
Assign the Point Code of
destination side on the DTI link.
Calling name indication is not sent
to destination party if switch is set
to Disable.
0: No setting
1: Channel number on the CCH
Package
Program 50 : Common Channel Interoffice Signaling Service
UNIVERGE SV8100
Input Data
Default
0~200
0
0 = 64Kbps
1
1 = 56Kbps
2 = 48Kbps(1)
3 = 48Kbps(2)
0
0~16367
0~16367
0
0 = Disable
1
1 = Enable
0-4
0