4. Hang the appliance on the wall
mounting bracket.
3.4 Safety valve installation
The water heaters are designed for a
maximum rated pressure of 1 MPa.
According to EN 60335-2-21 the safety
valve must prevent the water pressure to
exceed the maximum rated pressure of
the water heater from more than 0.1
MPa.
A type-examination tested safety valve is
required.
1. Install the safety valve in the cold
water supply line of the appliance.
2. Size the drain pipe so that water can
drain off unimpeded when the safety
valve is fully opened.
3. Fit the drain pipe of the safety valve
with a constant downward slope and
in a room free from the risk of frost.
WARNING!
The safety valve drain must
remain open to the
atmosphere.

4. CONTROL PANEL

Temperature selector knob.
1
If the supply pressure is
>0.48 MPa, install a pressure
reducing valve upstream of
the safety valve in the cold
water supply line.
3.5 Water connection
Carry out all water connection and only
install pressure taps in conjunction with a
safety valve accordance with regulations.
Match up the colour coding on the water
connections of the tap and the
appliance:
• R.h. side blue = "Cold water inlet"
• L.h. side red = "Hot water outlet"
Ensure that the water
connections are not kinked
during installation. Prevent
any tensioning during
installation.
Heat-up indicator lamp.
2
Depending on the system, the actual
1
temperatures may vary from the set
value.
* = Cold. On this setting, the appliance is
protected from frost. The tap, water lines
and safety valve are not protected.
2
MAX = Highest selectable temperature.