AEG GYE01016UE User Manual page 10

Electric storage
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
7.4 Setting the temperature
limit
Limiting ring
1
38 °C
2
49 °C
3
65 °C
4
Placing the limiting ring behind the
temperature selector allows you to limit
the setting range of the temperature
selector to a specific maximum
temperature.
1. Turn the temperature selector to
zero (fully clockwise to "*").
2. Pull off the temperature selector and
the limiting ring.
3. Push the limiting ring with the
required maximum setting onto the
appliance cover.
4. Install the temperature selector set to
zero ("*").
7.5 Activate high limit safety
cut-out
1. Open the appliance.
2. Pull off the adaptor.
3. Press the reset button on the high
limit safety cut-out.
4. Fit the adaptor.
5. Close the appliance cover.
6. Fit the limiting ring and temperature
selector.
1
2
2
3
4
Reset button, high limit safety cut-
1
out
Adaptor
2
7.6 Removing the flanged
immersion heater and
temperature controller / high
limit safety cutout
Combined temperature controller /
1
high limit safety cut-out.
Flanged immersion heater.
2
1. Remove the combined temperature
controller / high limit safety cut-out
from the flanged immersion heater.
2. Remove the flanged immersion
heater.
1
2
1