Sony SNC-WL862 Installation Manual page 12

Table of Contents

Advertisement

1
The +5V pin provides a 5V output voltage, and the max. load is 50mA.
2
The max. voltage for DO pins is 30V DC (External power).
In order to control AC devices, the Wet contact diagram can be taken in consideration. The diagram
uses a relay to control the ON/OFF condition of the AC device.
3
An external relay can be triggered by using +5V pin or by an external power source, depending on the
type of relay you use.
Dry contact and using camera's DO+ to supply a relay
Switch
NO
NC
Relay
External Device
12
External AC Power
with Protected Earth