7810iR-ent Internet/Intranet Alarm Receiver Installation and Setup Guide
Action
5. Touch the Install 7810iR button.
6. Backup receiver can be configured as
shown:
Configure all parameters:
4-14
Select role of This 7810iR as
Secondary
Select role of Other 7810iR as
Primary
Enter IP address of primary
receiver
Listening Port is used in Private
LAN mode only. This port is
programmed into the 7845i-ent.
Under normal circumstances there
is no need to change this port.
Compass Connect Port field is
used in Private LAN mode only.
Change in value of this port must
be coordinated with changes of IP
ports of other pieces of software
working in Compass connect.
Select Supervise Subs if you
want the secondary Central
Station to have the same
supervision interval as the primary
Central Station. If selected, the
communication module secondary
CS IP supervision must be
programmed for "Full Rate".
If the 7810iR-ent is programmed
for Supervise Subs, older 7845i-
ent units reporting to it without
the Full Rate option will not
recognize Full Rate supervision,
which will result in a comm.
failure to the second CS.
Therefore it is recommended you
do not select Supervise Subs if
any older 7845i-ent units are
reporting to this receiver.