Advertisement

Item
PERIOD
CYCLE
STD POSITION M.GAIN
STD POSITION VAR
STD POSITION ND
STD POSITION CC
IRIS PRIORITY
ROP DATA SAVE
ROP DATA LOAD
SD CARD FORMAT
INITIAL with NW
INITIAL
UPGRADE
IRIS CALIBRATION TOP
IRIS CALIBRATION BOTTOM
SYSTEM VERSION
SOFT VERSION
FPGA VERSION
Setting value
0 to 5
[PERIOD] and [CYCLE] will be the time from which [CALL] was released
for [CAMERA CCU].
PERIOD: Flashing duration (sec).
0.3
CYCLE: Flashing cycle (For 1.0: 500 msec off → 500 msec lit
0.5
1.0
(repeatedly)).
-6 to 0 to +36
Sets the standard position of the master gain (M.GAIN).
-2.9 to 0.0 to +2.9
Sets the standard position for master gain (M.GAIN) step values.
1 to 2 to 5
Sets the standard position of the ND filter.
A to E
Sets the standard position of the CC filter.
NON
Sets whether to prioritize iris control.
Serial
NON
LAN
Does not prioritize iris control.
If the camera's iris position does not match the ROP's [IRIS] lever pos-
ition, match the ROP's [IRIS] lever position to the camera's iris position.
Serial
If the camera's iris position does not match the ROP's [IRIS] lever pos-
ition, the ROP's [IRIS] lever position during serial connection will be the
basis of operation.
LAN
If the camera's iris position does not match the ROP's [IRIS] lever pos-
ition, the ROP's [IRIS] lever position during IP connection will be the
basis of operation.
NO?
Save the unit's setting information.
YES?
This applies to the following menus.
[ROP SETTING][CONNECT SETTING][CAMERA IP SETTING][ROP IP
SETTING]
After starting this process, do not turn off the unit or remove SD cards
until the process is complete.
NO?
Load the unit's setting information.
YES?
This applies to the following menus.
[ROP SETTING][CONNECT SETTING][CAMERA IP SETTING][ROP IP
SETTING]
After starting this process, do not turn off the unit or remove SD cards
until the process is complete.
NO?
Format the SD card.
YES?
NO?
Return the unit's settings to the factory default values.
YES?
This applies to the following menus.
[ROP SETTING][CONNECT SETTING][CAMERA IP SETTING][ROP IP
SETTING]
NO?
Return the unit's settings to the default values.
YES?
This applies to the following menus.
[ROP SETTING]
NO?
Updates the software of the unit.
YES?
After starting this process, do not turn off the unit or remove SD cards
until the process is complete.
-
IRIS CALIBRATION adjusts the operating range of the IRIS lever.
[IRIS CALIBRATION TOP] is executed when the IRIS lever is moved to
the OPEN end, and [IRIS CALIBRATION BOTTOM] is executed when it is
moved to the CLOSE end.
(Version display)
Displays the system version.
(Version display)
Displays the software version.
(Version display)
Displays the FPGA version.
- 113 -
Setting details
When multiple ROPs are IP connected to a single camera and the
[IRIS PRIORITY] setting for each ROP is set to "LAN", be aware
that iris controls from all of the ROPs will be performed directly.
ROP menu