z How the operating instructions are organized
• Basics:
This manual describes how to connect the unit to the required equipment and set it up.
Before installing the unit, be sure to read the <Basics> manual to ensure that you know how to install
it correctly.
• Operations and Settings (this manual)
Operations and Settings describe how to operate and set up the unit.
Before operating this product, please read the instructions carefully and save this manual for future use.
W1012MN6117 -PS

Operating Instructions

<Operations and Settings>
Remote Operation Panel
  AK-HRP200G
Model No.
ENGLISH
VQT4S52A-6 (E)

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic AK-HRP200G

  • Page 1: Operating Instructions

    Operating Instructions <Operations and Settings> Remote Operation Panel   AK-HRP200G Model No. z How the operating instructions are organized • Basics: This manual describes how to connect the unit to the required equipment and set it up. Before installing the unit, be sure to read the <Basics> manual to ensure that you know how to install it correctly.
  • Page 2: Table Of Contents

    „ About.trademarks.and.registered.trademarks. „ • SDHC logo is a trademark of SD-3C, LLC. • Other company names and product names appearing in this manual are the registered trademarks or trademarks of their respective companies. „ Copyrights „ It is prohibited to transfer, copy, disassemble, decompile, and reverse engineer the software included with the unit, as well as export it in violation of the export laws.
  • Page 3: Introduction

    For details, consult your supplier. „ Disclaimer.of.warranty „ IN NO EVENT SHALL Panasonic Corporation BE LIABLE TO ANY PARTY OR ANY PERSON, EXCEPT FOR REPLACEMENT OR REASONABLE MAINTENANCE OF THE PRODUCT, FOR THE CASES, INCLUDING BUT NOT LIMITED TO BELOW:...
  • Page 4: Operation.modes

    Operation.modes Operation.modes The unit has a serial connection mode and an IP connection mode. Serial connection mode The operation mode for use with a single CCU, remote camera, or camera recorder connected via a serial connection. Only one CCU, remote camera, or camera recorder can be controlled. (The camera switching operation is not possible.) The mode set at the time of shipment is serial connection mode.
  • Page 5: Operation Mode Setting Procedure

    Operation.modes. (continued) Operation.mode.setting.procedure In the factory default state, connect the CCU, remote camera or camera recorder to the unit and then set the operation mode. In the factory default state, connect the CCU, remote camera or camera recorder to the unit (for details, refer to Operating Instructions <Basics>).
  • Page 6: Setup.mode

    Setup.mode Setup.mode Setup mode allows the user to make a variety of unit settings, and save and load scene files and user files. Normal operation is unavailable during setup mode operation. ROP menu (REMOTE OPERATION MENU) operation is not available either. „...
  • Page 7 Setup.mode. (continued) „ Opening.setup.mode „ Exiting.setup.mode „ „ Setup mode differs from normal operating modes. Use the steps below To exit setup mode, hold down <EXIT> for two seconds. The unit returns to open setup mode. to normal operating mode. SYNC CAMERA When.a.camera.and.CCU.are.connected,.select.IRIS.(to.
  • Page 8 Setup.mode. (continued) „ Setup.mode.menu.configuration „ Setup mode is comprised of the menus and submenus listed in the table below. Default. Menu Submenu Set.value/Selected.operation value SYNC CAMERA SYNC CAMERA SYNC CAMERA M.GAIN M.PED 10-19 M.GAIN M.PED 10-19 M.GAIN M.PED 10-19 DATA DATA DATA IRIS...
  • Page 9 Setup.mode. (continued) „ Files.stored.on.a.memory.card „ In setup mode, the following files are saved to or loaded from a memory card by the unit. The fixed file names assigned by the unit must not be changed on a computer. If the file names are changed, they can no longer be processed by the unit. Files.stored.on.a.memory.card Filename Scene file...
  • Page 10: Setup.mode.operations

    Setup.Mode.Operations 2-1.Save.scene.file.to.memory.card 1.Set.camera.number Before switching to setup mode, open the scene file you wish to save Open.setup.mode.and.check.that.menu.number.[1].is. with the SCENE/USER FILE select buttons. (For details on how to open displayed..If.a.menu.number.other.than.[1].appears,. a scene file, refer to Operating Instructions <Basics>.) press.<SELECT>.to.select.menu.number.[1]. Press to select the camera number Press.<SAVE/LOAD>.to.select.[ND].
  • Page 11: 3.Saving.user.files.to/Loading.user.files.from.memory.card

    Setup.Mode.Operations. (continued) Press.<UP>.or.<DOWN>.to.select.a.file.number.on.the. Press.<UP>.or.<DOWN>.to.select.a.file.number.on.the. memory.card.and.press.<EXECUTE>.to.confirm.the. memory.card.and.press.<EXECUTE>.to.confirm.the. selection. selection. SYNC SYNC M.GAIN M.PED M.GAIN M.PED IRIS IRIS To load file no. 2 from the memory card To save a file to file no. 2 on the memory card Press.<UP>.or.<DOWN>.to.select.[y].and.press. Press.<UP>.or.<DOWN>.to.select.[y].and.press. <EXECUTE>.to.confirm.the.selection. <EXECUTE>.to.confirm.the.selection.
  • Page 12: Save Lens File To/Load Lens File From Memory Card

    Setup.Mode.Operations. (continued) Press.<UP>.or.<DOWN>.to.select.[y].and.press. Press.<UP>.or.<DOWN>.to.select.[y].and.press. <EXECUTE>.to.confirm.the.selection. <EXECUTE>.to.confirm.the.selection. • Do not remove a memory card that is being accessed. • Do not remove a memory card that is being accessed. SYNC SYNC M.GAIN M.PED M.GAIN M.PED IRIS IRIS • To cancel loading, select [n] and press <EXECUTE>. •...
  • Page 13: Save Rop Configuration File To/Load Rop Configuration File From Memory Card

    Setup.Mode.Operations. (continued) Press.<SAVE/LOAD>.to.select.[CC]. 5.Save.ROP.configuration.file.to/load.ROP. • Each press of <SAVE/LOAD> toggles between [ND] (Save) and configuration.file.from.memory.card [CC] (load). Press.<SELECT>to.select.menu.number.[5]. SYNC Save file indication Select y (Select)/ M.GAIN M.PED Load file indication n (Cancel) SYNC CAMERA M.GAIN M.PED 10-19 IRIS DATA Press.<UP>.or.<DOWN>.to.select.[y].and.press. <EXECUTE>.to.confirm.the.selection.
  • Page 14: Select/Set Flare And Pedestal

    Setup.Mode.Operations. (continued) Press.<UP>.or.<DOWN>.to.select.[on].and.press. 7.Select/set.flare.and.pedestal <EXECUTE>.to.confirm.the.selection. Press.<SELECT>to.select.menu.number.[7]. SYNC Select FL (Flare)/PE (Pedestal) M.GAIN M.PED SYNC CAMERA M.GAIN M.PED 10-19 IRIS DATA • To exit setup mode, hold down <EXIT> for about 2 seconds. • To make other settings, press <SELECT> to select a menu number. IRIS DOWN DISPLAY SELECT...
  • Page 15: Set Ip Address

    Setup.Mode.Operations. (continued) Press.<UP>.or.<DOWN>.to.select.7-segment.display. 11.Set.subnet.mask brightness.and.press.<EXECUTE>.to.confirm.the. Press.<SELECT>.to.select.menu.number.[11]. selection. • Block 1 of the subnet mask appears. SYNC Display/set block 1 M.GAIN M.PED Display/set block 2 Press to select Display/set block 3 the subnet mask Display/set block 4 IRIS CAMERA SYNC M.GAIN M.PED 10-19 •...
  • Page 16: 12.Set.default.gateway

    Setup.Mode.Operations. (continued) For the default gateway, you can set a value within the following 12.Set.default.gateway ranges. Press.<SELECT>.to.select.menu.number.[12]. Block 1 0 to 255 • Block 1 of the default gateway appears. Block 2 0 to 255 Block 3 0 to 255 Display/set block 1 Block 4 0 to 255...
  • Page 17: Set Serial

    Setup.Mode.Operations. (continued) Save.remote.camera.configuration.file.to.memory.card Press.<UP>.or.<DOWN>.to.select.[y].and.press. <EXECUTE>.to.confirm.the.selection. Press.<SAVE/LOAD>.to.select.[ND]. • Do not remove a memory card that is being accessed. • Each press of <SAVE/LOAD> toggles between [ND] (Save) and SYNC [CC] (Load). M.GAIN M.PED SYNC M.GAIN M.PED IRIS • To cancel loading, select [n] and press <EXECUTE>. IRIS •...
  • Page 18: Initialize Settings

    Setup.Mode.Operations. (continued) 16.Initialize.settings 18.Save.unit.data.to.memory.card This function is used by the manufacturer during maintenance. <Note> When settings are initialized, the unit is automatically restarted.For Press.<SELECT>to.select.menu.number.[18]. details on what settings are initialized, refer to page 8 Select y (Save)/n (Cancel) Press.<SELECT>to.select.menu.number.[16]. SYNC CAMERA Select y (Initialize)/n (Cancel) M.GAIN...
  • Page 19: Set Tally Number

    Setup.Mode.Operations. (continued) Press.<UP>.or.<DOWN>.to.select.[y].and.press. Press.<UP>.or.<DOWN>.to.select.[on].and.press. <EXECUTE>.to.confirm.the.selection. <EXECUTE>.to.confirm.the.selection. • Upgrading starts. SYNC SYNC M.GAIN M.PED M.GAIN M.PED IRIS IRIS • To exit setup mode, hold down <EXIT> for about 2 seconds. • When the upgrade ends, [Fin] appears and the unit restarts •...
  • Page 20: Error Messages In Setup Mode

    Setup.Mode.Operations. (continued) Press.<UP>.or.<DOWN>.to.select.the.setting.number,. and.press.<EXECUTE>.to.confirm.the.selection. SYNC M.GAIN M.PED IRIS • To make other settings, press <SELECT> to select a menu number. Error.messages.in.setup.mode Error.No. Error.data A file with the same name already exists. Select [y] to overwrite. An error occurred on the memory card. •...
  • Page 21: Rop.menu.operations

    ROP.menu.operations ROP.menus.that.can.be.operated.on.the.unit Operating.ROP.menus The unit can access the picture monitor on a CCU to control the ROP „ Basic.menu.operations „ menu (REMOTE OPERATION MENU). <Note> Hold.down.<CHARA/MENU>.for.2.seconds. ROP menu operation is a function that is enabled when the unit is The [REMOTE OPERATION MENU] appears. (The cursor appears at connected to AK-HCU200.
  • Page 22 ROP.menu.operations. (continued) „ Operating.other.menus „ When a menu has more than one setting on a line, press <SELECT> (to confirm) and the cursor [] appears. Turn <SELECT> right or left to move the cursor to the input area. Cursor movement ** SHADING...
  • Page 23: Rop.menu.setting

    ROP.menu.setting The following describes [ROP MENU] settings. PEDESTAL/FLARE/GAIN SHADING(WHITE) →** PEDESTAL/FLARE/GAIN ** FLARE SWITCH  ON → ** SHADING ( WHITE )  ** R G B WHITE SHADING SWITCH  ON PEDESTAL 0 0 0 HSAW HPARA VSAW VPARA FLARE 0 0 0 R       0     0    0     0 GAIN 0 0 G       0     0    0     0 B       0     0    0     0...
  • Page 24: Gamma/Black. Gamma

    ROP.menu.setting. (continued) GAMMA/BLACK..GAMMA Item Display Function GAMMA.B zWhen [GAMMA Adjusts B gamma correction MODE SEL] relative to M gamma. → ** GAMMA/BLACK.  GAMMA ** is [HD] and GAMMA SWITCH ON [CINEMA GAMMA MODE SEL HD GAMMA R M B SWITCH] is GAMMA 0 0. 450 0...
  • Page 25: Cinema Gamma

    ROP.menu.setting. (continued) CINEMA.GAMMA KNEE/WHITE.CLIP <Note> <Note> • The settings in this menu are not available when the [CINEMA • Some settings in this menu are not available when the [CINEMA GAMMA SWITCH] is set to [OFF]. GAMMA SWITCH] is set to [ON]. →** CINEMA GAMMA **...
  • Page 26: Color Control

    ROP.menu.setting. (continued) COLOR.CONTROL Item Display Function Adjusts the saturation and color ‫׀‬ phase of G and R components →** COLOR CONTROL ** in matrix memory. ‫׀‬ CHROMA LEVEL SWITCH OFF CHROMA LEVEL 0% Adjusts the saturation and color COLOR TEMP SWITCH OFF ‫׀‬ phase of G and B components in COLOR TEMP VALUE...
  • Page 27: Hd Dtl/Skin Dtl (1/2)

    ROP.menu.setting. (continued) HD.DTL/SKIN.DTL.(1/2) Item Display Function +GAIN Changes the detail gain level in ‫׀‬ + (up) direction →** HD DTL/SKIN DTL ( 1/2 )  ** ‫׀‬ DETAIL SWITCH ON V DETAIL 20 H DETAIL 20 -GAIN Changes the detail gain level in - CRISP 10 ‫׀‬ (down) direction PEAK...
  • Page 28: Sd Detail

    ROP.menu.setting. (continued) Item Display Function Item Display Function MEM.A.WIDTH Expands the width of skin tone PEAK2 OFF/1.89M/ Selects one of the two contour ‫׀‬ 2.18M/2.56M/ areas in memory bank A in a correction frequency bands range from 0 to 255. 3.17M/4.00M/ (boost frequency or peak .5.28M/6.75M...
  • Page 29: System (2/2)

    ROP.menu.setting. (continued) SYSTEM.(2/2) Item Display Function UP.CONVERT. Selects the video up- MODE conversion system used →** SYSTEM  ( 2/2 )  ** for SD SDI and VBS return videos. HD H PHASE 0 Select the signal format for SD H PHASE 0 input. SD-HD V 0H HD.COLOR.BAR FULL Select the color bar signals to be BARS-1...
  • Page 30: Function

    ROP.menu.setting. (continued) Item Display Function Item Display Function MIC1.AMP -20dB Makes fine adjustments of the ASU.FILTER Sets the operation of the ND ‫׀‬ CURRENT MIC1 gain. filter when auto setup is started. ‫׀‬ (in.1.dB.increments) REF: 20dB The filter stored in the reference file is used when MIC2.GAIN 20dB...
  • Page 31: Lens File/Edit (2/2)

    ROP.menu.setting. (continued) LENS.FILE/EDIT.(2/2) ROP.SD.CARD Scene files, user files, and lens files can be saved to or loaded from a →** LENS FILE/EDIT ( 2/2 )  ** memory card of the ROP. Open the scene file and user file you wish to save with the SCENE/ EXTENDER...
  • Page 32: Ip.connection

    IP.connection IP.setting.procedure The following describes the setting procedure for IP connection of this unit to CCUs, remote cameras and camera recorders. For the system configuration when using IP connections, refer to Operating Instructions <Basics>. For operation using just a serial connection (serial connection mode), the following IP address settings are not necessary. Installing.the.software Easy IP Setup Software is a tool for setting the IP addresses of the ROP, remote cameras, Install.Easy.IP.Setup.Software.and.ROP.Setup.Software.
  • Page 33: How To Start The Software

    How.to.Start.the.Software Setting.the.IP.addresses.of.the.devices Visit the product support desk of the following website to download the „ Configuring.the.settings.using.the.menus „ software. Set the IP address of the unit (ROP) in setup mode. http://pro-av.panasonic.net/ Item Reference.page IP address page 15 „ Installing.Easy.IP.Setup.Software „ Subnet mask page 15 <Note>..
  • Page 34: Easy.ip.setup.software

    Easy.IP.Setup.Software <Note> Setting.IP.addresses.of.devices • If a firewall is activated, set the web browser or Easy IP Setup Use Easy IP Setup Software to set the IP address of each device. Software to the “Allow a program through Windows Firewall” setting. <Note>...
  • Page 35: Rop.setup.software

    ROP.Setup.software First, register the IP address of the ROP on the [ROP List] tab of the Register.the.unit.in.the.ROP.Setup.Software.[ROP.List]. ROP Setup Software. On the [ROP List] tab, register the IP address of the unit in [HRP1] of the Once the IP address has been registered, configure the settings of ROP Setup Software.
  • Page 36: Configuring The Unit Settings [Configuration]

    ROP.Setup.software. (continued) Configuring.the.Unit.Settings.[Configuration] Making.Camera.Connection.Settings.[Camera.List] Configure the settings of the unit in the [Configuration] tab. On the [Camera List] tab, configure settings for connections between When you connect the personal computer to the unit for the first time, the ROP and the cameras. When you connect the personal computer to click the [REFRESH] button (2) to acquire the values set on the unit.
  • Page 37 ROP.Setup.software. (continued) CAMERA.NO.(5) CAMERA.PORT.NO.(10) Displays the camera numbers. Set the port numbers of cameras being connected. After input, click the [SET] button (14) to reflect the changes. <NOTE> In serial connection mode, only the camera number configured in Possible setting 1 to 65535 range: [CAMERA NUMBER(SERIAL)](4) can be connected.
  • Page 38 ROP.Setup.software. (continued) <Note> z Caution when setting camera numbers Be careful with regards to the following points when configuring the settings in [Camera List] for each HRP200. • Decide the number of each camera beforehand, and set [Camera List] so that each camera number becomes the same as in the settings of all ROPs.
  • Page 39: Set Up User Authentication [User Auth.]

    ROP.Setup.software. (continued) z User.authentication.for.camera.recorders Set.up.user.authentication.[User.Auth.] User authentication is always enabled for camera recorders. To control CCUs, remote cameras or camera recorders that have the In order to use IP connection with camera recorders, set user user authentication function enabled, you need to set the user name and authentication as follows.
  • Page 40: Index

    Index Setup mode .................... SHADING(WHITE) ................Camera number ................... Syncro shutter ..................CINEMA-GAMMA ................SYSTEM ..................COLOR CONTROL ................Confirm version ................... Tally control setting ................Easy IP Setup Software ............... Error display ..................Upgrade ....................User file ....................Load .................... Format (memory card) .................