Panasonic AK-HRP200G Operating Instructions Manual

Remote operation panel

Advertisement

Für Erlauterungen in Deutsch, konsultieren Sie bitte die mitgelieferte CD-ROM.
DEUTSCH
(→ Seite 4)
Pour des explications en français, veuillez vous reporter au CD-ROM fourni.
FRANÇAIS
(→ page 4)
Per le istruzioni in italiano, vedere il CD-ROM in dotazione. (→ pagina 4)
ITALIANO
Para la explicación en español, consulte el CD-ROM suministrado. (→ página 4)
ESPAÑOL
日本語版の取扱説明書は付属のCD-ROMに納められています。(→4ページ)
日本語
This manual is also contained as a PDF file on the CD-ROM supplied with the unit. (→page 4)
Before operating this product, please read the instructions carefully and save this manual for future use.
FJ1012KT0 -PS
Printed in Japan

Operating Instructions

Remote Operation Panel
  AK-HRP200G
Model No.
● How●the●operating●instructions●are●organized
・● Basics●(this●manual):
This manual describes how to connect the unit to
the required equipment and set it up.
Before installing the unit, be sure to read the
<Basics> manual to ensure that you know how to
install it correctly.
The <Basics> manual is provided as a PDF file on the
CD-ROM supplied with the unit.
・● Operations●and●Settings:
Operations and Settings describe how to operate
and set up the unit.
The <Operations and Settings> manual is provided
as a PDF file on the CD-ROM supplied with the unit.
● To●read●PDF●files,●you●will●need●Adobe
You●can●download●it●from●Adobe●Systems'●website.
<Basics>
®
®
●Reader
.●
ENGLISH
VQT4S52

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic AK-HRP200G

  • Page 1: Operating Instructions

    Operating Instructions <Basics> Remote Operation Panel   AK-HRP200G Model No. ● How●the●operating●instructions●are●organized ● ・● Basics●(this●manual): This manual describes how to connect the unit to the required equipment and set it up. Before installing the unit, be sure to read the <Basics>...
  • Page 2: Read This First

    EEE Complies with Directive of Turkey. Note: The rating plate (serial number plate) is on the bottom of the unit. Importer’s name and address of pursuant to EU rules: Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15, 22525 Hamburg, Germany...
  • Page 3: Important Safety Instructions

    Read this first! (continued) EMC NOTICE FOR THE PURCHASER/USER OF THE APPARATUS 1. Applicable standards and operating environment (AK-HRP200) The apparatus is compliant with: • standards EN55103-1 and EN55103-2 2009, and • electromagnetic environments E1 - E5. 2. Pre-requisite conditions to achieving compliance with the above standards <1>...
  • Page 4 Read this first! (continued) ENGLISH ITALIANO „ How to open the operating instruction manual PDF files „ Come aprire i file dei manuali di istruzioni per l’uso „ „ Discontinue installation if the installation screen of the software opens as Se inserendo il CD-ROM si apre la schermata di installazione del a result of inserting the CD-ROM.
  • Page 5: Table Of Contents

    The following abbreviations are used in this manual. • The AK-HRP200G is referred to as the AK-HRP200 in this manual. • The term memory card will be used below as a generic term for both SD and SDHC memory cards.
  • Page 6: Introduction

    • Avoid locations exposed to high temperature and humidity • Avoid exposure to condensation • Avoid static electricity. „ Software upgrades „ For upgrades, visit Support & Download on the Panasonic website. http://panasonic.biz/sav/ Follow the instructions included in the download file to perform the upgrade. „ Disclaimer „...
  • Page 7: Features

    Features z This unit is a remote operation panel for controlling a studio handy camera (AK-HC3800) and a camera controller unit like the AK-HCU200. z A simple button layout and an IRIS control lever ensure intuitive and stable operation. z Scene files, user files and lens files can be stored on memory cards. Accessories Make sure that the following accessories are supplied.
  • Page 8: Precautions For Installation

    Precautions for installation Observe the following in addition to the information included in “Read this first!”. Have your supplier install the unit and handle connections. „ Cable connections „ Installation location „ „ • Be sure to use dedicated remote operation panel (ROP) cables. •...
  • Page 9: System Component Connections

    Setting up the unit (continued) System component connections Connect the CCU connector on this unit to the ROP connector on the CCU rear panel using a dedicated ROP cable (sold separately). After having connected all the components, turn the CCU Connection example: main power on, and then turn the camera on.
  • Page 10: Parts And Their Functions

    Parts and their functions Operation panel A beep (buzzer) sounds when a button is pressed. However, buttons do not beep when the buzzer is set to Off in setup mode. AUTO HEAD POWER POWER BARS WHITE BLACK SET UP TEST KNEE SHUTTER 5600K...
  • Page 11 Parts and their functions (continued) Auto Setup button <SETUP> Knee OFF button <KNEE OFF> Use this button to start auto setup. Use this button to cancel the knee function that attenuates those The setup status is output to the picture monitor. areas of the video signals where a particular level (knee point) has Choose [FUNCTION] ...
  • Page 12 Parts and their functions (continued) SCENE/USER FILE SHIFT SCENE 1 SCENE 2 SCENE 3 SCENE 4 STORE USER 1 USER 2 USER 3 Scene/User File selector button <SHIFT> Scene/user file store button <STORE> Use this button to determine whether the SCENE/USER FILE Use this button to store your own scene files (1 to 4) or user files (1 select button will be used for selecting scene files or user files.
  • Page 13 Parts and their functions (continued) GAIN VR LOCK FLARE/PED Control lock button <VR LOCK> B gain control <GAIN B> Use this button to lock (disable) the paint control operation. It controls Use this control to adjust the blue (B) components of the white GAIN (R, B), PED/FLARE (R,B) and DTL paint.
  • Page 14 Parts and their functions (continued) 28 33 34 31 CAMERA SYNC M.GAIN M.PED 10-19 DATA IRIS DOWN DISPLAY SELECT SELECT SET UP ND/CC M.GAIN/M.PED SHUTTER SHIFT UP+DOWN SAVE/LOAD EXIT EXECUTE DATA SET button <UP> ND filter/CC filter DISPLAY SELECT button <ND/CC> Use this button to increase set values when ND filter/CC filter, SAVE/LOAD button <SAVE/LOAD>...
  • Page 15 Parts and their functions (continued) M.GAIN/M.PED DISPLAY SELECT button <M.GAIN/ 3. Press <SHUTTER> again. The button goes off and the SHUTTER display <SHT> goes off. M.PED> Then the setting display returns to IRIS indication. EXIT button <EXIT> (In setup mode) Pressing another Display Select button (<ND/CC>...
  • Page 16 Parts and their functions (continued) CHARA IRIS/M.PED LOCK IRIS M.PED PUSH MENU PREVIEW TALLY/CALL SENSE SELECT D.EXT AUTO COARSE CLOSE OPEN CLOSE FULL Character/Menu button <CHARA/MENU> Alarm display <ALM> Use this function to switch on and off the characters (status screen) This indicator displays alarms.
  • Page 17 Parts and their functions (continued) Iris lever <IRIS ( )> Sense control <SENSE> Use this to control the iris level. Use this control to adjust the iris range when the iris lever is moved from the center to the upper and lower edges. This function is enabled when the iris/master pedestal lock is released.
  • Page 18: Connector Panel

    Parts and their functions (continued) Connector Panel RS-422 PREVIEW SIGNAL GND CCU connector <CCU> RS-422 connector <RS-422> (RJ-45 connector) (Hirose Electric: HR10A-10R-10P (71)) This connector is designed for future use. Do not use this connector. Connect this connector to the CCU of a camera. IP connector <LAN>...
  • Page 19: Specifications

    Specifications „ General PREVIEW control : Contact output „ Maximum cable length : 50 m (164 ft) Power input Operating temperature : 0 °C to 40 °C (32 °F to 104 °F) Power supply: 12 V DC, 0.35 A (DC input range; 10 V DC - 16 V DC) Storage temperature : −20 °C to 60 °C (−4 °F to 140 °F) Power consumption: 4.2 W...
  • Page 20 This symbol is only valid in the European Union. If you wish to discard this product, please contact your local authorities or dealer and ask for the correct method of disposal. Web Site: http://panasonic.net プロフェッショナルAVビジネスユニット 〒 571-8503 大阪府門真市松葉町 2 番 15 号...

Table of Contents