Mounting and Wiring the Panel Link Module
The PLM will not operate until the device is enabled in the control's Device Programming in #93 Menu Mode .
Do not mount the PLM on the cabinet door or attempt to attach it to the PC board.
To mount and wire the Panel Link Module, refer to Figure 3-27 and perform the following steps:
Step
Action
1
Remove all power from the control panel before making any wiring connections.
2
Mount the module in the control cabinet if space is available or, adjacent to the cabinet, using 2-faced
adhesive tape.
3
Set the PLM's DIP switches for a device address between 01 and 30. See the module's instructions for the
DIP switch table.
Do not use an address being used by another device (keypads, RF receivers, etc.).
4
Connect the 12V (+) and (–) and data-out and data-in connections from the PLM to the control's keypads
terminals (6, 7, 8, and 9), respectively.
5
Connect the 3-wire RS-485 cable between each PLM. Recommended wiring is to bring the wires "in" from
one module (or control panel) to terminals 5 (+), 6 (-), and 7 (G) and "out" to the next module from terminals
TB1-8 (+), 9 (-), and 10 (G).

Communicator Connected to the J7 Triggers

These triggers may be used to trip auxiliary alarm signaling equipment such as Honeywell's 7845GSM, 7845iGSM, and
7847i, Communicators. The triggers are common to all partitions and must be enabled for each partition (field 2✳20).
The fire and burglary/audible panic alarm triggers are normally LOW and go HIGH until a User Code + OFF is
entered in all enabled partition(s) that display these conditions. The silent panic/duress trigger latches HIGH, except for
duress, which is momentary.
Refer to the installation instructions that accompany your Communicator for the connections to the control panel.

Communicator Connected to the ECP

The control can support an ECP Communicator (7845GSM, 7845i-GSM, 7845i-ent and 7847i are supported) that
connects to control panel's keypad terminals. All messages programmed for transmission via the phone lines may also
be sent via the Communicator. These messages are transmitted in Contact ID format regardless of the format
programmed for the control in fields 45 and 47.
TAMPER
REED
SWITCH
PIEZO
SOUNDER

Figure 3-27: VA8200 Panel Link Module Wiring

DIP
SWITCH
1 2 3 4 5 6 7 8
+
_
ECP OUT
ECP IN
+
_
G
+
_
G
EOL
JUMPER
PINS
PLG-002-V0
Installing the Control
RS-485
RS-485
3-23