Ph Sensor Systems Connections; Standard Ph Systems Connection - 2867, Ap100, Ap300, 7650/60, Tb5, Non-Abb - ABB AX400 Series User Manual

Single and dual input analyzers for ph/redox (orp)
Hide thumbs Also See for AX400 Series:
Table of Contents

Advertisement

Single and dual input analyzers for pH/Redox (ORP)
AX416, AX436, AX460, AX466 & AX468

6.6 pH Sensor Systems Connections

6.6.1 Standard ph Systems Connection – 2867, AP100, AP300, 7650/60, TB5, Non-ABB
When connecting one of these pH systems to the AX400 transmitter, ensure the differential input switch for the relevant sensor
is
.
OFF
Terminal Block B
Sensor B
Sensor A
B1
B9
B2
B10
B3
B11
B4
B12
B5
B13
B6
B14
B7
B15
B8
B16
Table 6.1 Standard ph Systems Connection – 2867, AP100, AP300
Terminal Block B
Sensor B
Sensor A
B1
B9
B2
B10
B3
B11
B4
B12
B5
B13
B6
B14
B7
B15
B8
B16
*See Note 2
Table 6.2 Standard ph Systems Connection – 7650/60, TB5, Non-ABB
Note.
1. If the sensor is fitted with a 2-wire PT100, Pt1000 or 3K Balco temperature compensator, link terminals B9 and B10 (and
B1 and B2 if dual input analyzer).
2. Discard large green wire as not required with this transmitter.
3. Redox systems are not temperature compensated so do not have temperature sensors. To remove temperature error
messages, set
Temperature Sensor
to the correct type – see Section 5.3, page 30.
Temperature Sensor
54
Function
Temperature Compensator (if fitted) Common –
see also Note 1below
Temperature Compensator (if fitted) 3
Temperature Compensator (if fitted)
Not Used
Not Used
Reference Electrode
Screen/Shield (if fitted)
Glass/Metal Electrode
Function
Temperature Compensator (if fitted) Common –
see also Note 1below
Temperature Compensator (if fitted) 3
Temperature Compensator (if fitted)
Not Used
Not Used
Reference Electrode
Screen/Shield (if fitted)
Glass/Metal Electrode
to
. If a temperature sensor is used for a separate temperature display, set
NONE
2867
Color
Not Used
rd
Lead
Not Used
Not Used
Not Used
Not Used
Black
Not Used
Clear
*7650/60
Color
Red
rd
Lead
Red
White
Not Used
Not Used
Black
Yellow
Clear
6 Installation
AP100
AP300
Color
Color
Red
White
Red
Grey
White
Red
Not Used
Not Used
Not Used
Not Used
Black
Black
Not Used
Not Used
Clear
Blue
TB5
Non-ABB
Color
White
Link to White
Connect as per
Red
function –
refer to
Not Used
(non-ABB)
sensor system
Not Used
manual for cable
colors
Black
Not Used
Blue
IM/AX4PH Rev. P

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ax416Ax466Ax468Ax436Ax460

Table of Contents