Codes - Honeywell Accenta Engineer's Manual

Hide thumbs Also See for Accenta:
Table of Contents

Advertisement

Codes (contd)
LED Keypad:
To change the Rearm Count:
.
Press [7] to enter Timers.LED's 1, 2 and 3 are on.
Press [3] for Rearm Count. LED 1 is on.
Select a number [0 - 9] to change the rearm count.
To accept the change press
Press
.
OR to cancel the change press

8 = Codes

There are four codes used in the system, all are 4 digit and can be set to any number from 0000 to 9999. The
access codes ensure that only authorised users can operate the system.
User 1 and 2 codes
The user 1 and user 2 codes have the same operation for testing, Setting and Unsetting, but user 1 code which
is usually considered to be the Manager's code has the authority to add, change or delete the user 2 code and
duress code.
Duress code
Should be used in a hold up situation where there is pressure to Set or Unset the system. Entry of the code
will allow the system to work normally but also generate a silent SOS type alarm by operating the PA commu-
nicator output. The duress code is not applicable for Optima Compact system.
Engineer code
Accesses the Engineer program mode to allow the system to be programmed. The engineer code will not set
or unset the system.
If configured the Engineer's code can be used to reset the system after an alarm.
NOTE: Entering an invalid user code will operate the code tamper. After 17 incorrect keypushes a full alarm
condition will be generated.
Accenta/Optima Engineer's Manual
. LED's 1, 2 and 3 are on.
twice.
28
[7]
4
1
2
3
5
6
7
[3]
3
4
5
6
7
1
2
[Number]
4
5
7
1
2
3
6
then
or
1
2
3
4
5
6
7
8
8
8
8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Optima8ep4168sp399a8ep396a8ep417a

Table of Contents