Accenta/Optima Engineer's Manual
Keypad
Board
0V
13V
COMMS
SOUND
TAMP
TB1
+13V 0V sound
tamp tamp
Keypad PCB

Connecting Remote Keypads

NOTE: Where an Accenta Mini panel is being installed, make sure there is at least one remote keypad
wired to the panel before the first power up.
Up to four remote LCD or LED keypads can be connected to the panel. Wire the keypad(s) as per Figure 5
(LED keypad) or Figure 6 (LCD keypad).
NOTE: When the panel back-up battery is charging, the LCD keypad backlight may not operate.
Keypad
Board
0V
13V
COMMS
SOUND
TAMP
Figure 5. Connecting LED keypads to panel
TB2
TB1
comms
+13V 0V sound
Keypad PCB
Figure 6. Connecting LCD keypads to panel
Connecting Keypads
A maximum of up to Four
Remote Keypads allowed
Panel
Board
J5
TB2
tamp tamp
comms
Panel
5
SOUND
RKP FUSE
COMMS
1A
F2
+13V
0V
TAMP
Board
SOUND
COMMS
RKP FUSE
1A
+13V
0V
TAMP
5
F4

Hide quick links: