Programs (contd)
Immediate (Intruder) Zone
This is a zone which will, when enabled as used and then activated, go into alarm when the panel is set. To
assign a zone as immediate, remove the timed or timed inhibit function and make sure that it is enabled in the
Used Zones section.
4 = Entry Time
This is the time allowed to enter the premises via the entry route and unset the system. The programmable
range is 00-99 seconds. The actual time is multiplied by 10.
00 = 5 seconds
01 = 10 seconds
03 = 30 seconds
99 = 990 seconds (16.5 minutes)
The default is 30 seconds.
LCD Keypad:
While in Engineer program mode, to set the entry time,
Press
to give a choice of programs or press [up arrow] until
P>Programs is displayed
Select program 1, 2 or 3.
The first screen to appear is Program Edit Used
Zones.
Press [4] to enter into Entry Time edit. The Entry
Time can now be changed.
Enter a [2-digit number] from 00 to 99.
Press
to accept change or
cancel.
Press [RESET] twice to leave menu.
LED Keypad:
While in Engineer program mode, to set the entry time,
Press
to give a choice of programs.LED's 1,
2 and 3 are flashing.
Select program 1, 2 or 3. If program 1 is selected,
LED 1 is ON.
Select [4] to enter into Entry Time edit. The Entry
Time can now be changed. LED 1 is ON.
Enter a [2-digit number] from 00 to 99. LED 1 is
ON.
Press
to accept change or
Press
twice to leave menu.
Accenta/Optima Engineer's Manual
then press
.
to
to cancel.
38
P>Select Program
1 2 or 3
[Number]
P>Program Edit
Used Zones
[4]
P>Program Edit
Entry Time? --
[2-digit number] then
P>Program Edit
Entry Time
P>Programs
1
2
3
4
5
[1]
1
2
3
4
5
[4]
1
2
3
4
5
[2-digit number]
then
or
4
1
2
3
5
3
4
5
1
2
or
6
7
8
6
7
8
6
7
8
8
6
7
6
7
8