53 - Program Outputs (cont'd)
Use the A or B key to select the required group (A1–D8). When the end of a block is reached, the next
block of eight groups is selected; press keys 1–8 to toggle the status of the relevant group in the current block
to the output; press the ent key to accept the selection.
Group Status
This group attribute offers an additional feature that makes the operation of the output conditional on the set
status of each of the system groups. An output assigned Group Status only activates if the set conditions of
the programming are met, for example, an Intruder output used to trigger a communicator can be pro-
grammed to activate only if groups 2 and 4 are set and group 3 is unset.
To assign the Group Status conditions, press the
on the bottom line as well as the current Status. Press the relevant number keys to toggle the status of the
groups and press the ent key to accept the programming. The available group status conditions are:
S
=
Set — group must be set to allow output to activate;
U
=
Unset — group must be unset to allow output to activate;
=
Set or unset — output activation is independent of the group status.
Galaxy Programming Manual
Groups
12345678
STATUS >-SUS----
key when selecting the groups: an arrow (>) is displayed
84