Honeywell Galaxy 18Galaxy Programming Manual page 59

Hide thumbs Also See for Galaxy 18Galaxy:
Table of Contents

Advertisement

Galaxy Programming Manual
NOTES:
1. A Final zone assigned a
Time for the group it is allocated to.
2. There are no groups in the Galaxy 8
06 = System Reset
This option allows the engineer or the remote code to determine the code level that can reset the system
following an intruder alarm. The default level is 6 — manager; the programmable range is:
• 0–5 for the user
• 6 for the manager
• 7 for the engineer
This parameter can be assigned a different value for each group.
NOTE: 1. There are no groups in the Galaxy 8.
2. This option is affected by reduced resets, menu option 51.55.3.
The panel only requests Engineer Level Reset if Intruder, PA or Tamper alarms have been signalled, via the
Telecom Module and appropriate level reset is set to 7. If no signal is transmitted, the reset will automatically
reduced to level 6. This feature is only active when the DTMF signalling format is selected.
07 = Tamper Reset
This option allows the engineer or the remote code to determine the code level that can reset the system
following a tamper. The default level is 7 — manager; the programmable range is:
• 0–5 for the user
• 6 for the manager
• 7 for the engineer
This parameter can be assigned a different value for each group.
NOTE: 1. There are no groups in the Galaxy 8.
2. This option is affected by reduced resets, menu option (51.55.3)
The panel only requests Engineer Level Reset if Intruder, PA or Tamper alarms have been signalled, via the
Telecom Module and appropriate level reset is set to 7. If no signal is transmitted, the reset will automatically
reduced to level 6. This feature is only active when the DTMF signalling format is selected.
08 = No. Re-Arms (Galaxy 8, 18, 60, 128, 500, & 504)
The Number of Re-arms parameter determines the number of times that an armed system can re-arm the
bells, following an alarm activation. The default setting is 9 (infinite) with a programmable range of 0 – 9,
where 9 is infinite re-arm. If the option is enabled, then the system re-arms at the end of the programmed
confirm time - only if all zones are closed or are open and can be omitted, or if the Omit all force is enabled.
The intruder output remains active until a system re-arm occurs.