Honeywell ADEMCO VISTA-120 Installation And Setup Manual page 78

Partitioned security system with scheduling
Hide thumbs Also See for ADEMCO VISTA-120:
Table of Contents

Advertisement

VISTA-120 Installation and Setup Guide
Note that these codes are independent of the relay
codes programmed during Output Programming in the
#93 Menu Mode located in the Programming Guide.
Relay Commands
Action Code
Action
01
Relay On
02
Relay Off
03
Relay Close for 2 seconds
Relay Close XX minutes (set
04
in field 1*74)
Relay Close YY seconds (set
05
in field 1*75)
06
Relay Group On
07
Relay Group Off
Relay Group Close for 2
08
seconds
Relay Group Close XX
09
minutes (set in field 1*74)
Relay Group Close YY
10
seconds (set in field 1*75)
Arm/Disarm Commands
Action Code
Action
20
Arm-STAY
21
Arm AWAY
22
Disarm
Force Arm STAY (Auto-
23
bypass faulted zns)
Force Arm AWAY (Auto-
24
bypass faulted zns)
25
Arm INSTANT
26
Arm MAXIMUM
The auto-arm warning (field 2*06) applies when
using Time-Driven events to auto-arm.
Temporary schedules do not override an auto-
arming or auto-disarming programmed in Time-
Driven events.
The auto-arming time period cannot be extended
using the Installer Code + #82 Mode.
Bypass Commands
Action Code
Action
30
Auto bypass – Zone list
31
Auto unbypass – Zone list
Open/Close Time Periods
Action Code
Action
Enable Opening Time Period
40
by partition
Enable Closing Time Period
41
by partition
Enable Access Time Period
42
for access group
6-8
Access Control Commands
Action Code
55
56
Action Specifier
57
Relay #
58
Relay #
59
Relay #
60
Relay #
61
Relay #
62
Relay Group #
63
Relay Group #
64
65
Relay Group #
66
Relay Group #
67
68
Relay Group #
69
Action Specifier
70
Partition(s)
Partition(s)
71
Partition(s)
72
Partition(s)
73
74
Partition(s)
77
Partition(s)
78
Partition(s)
3.
Activation
Action Specifier
Zone list #
Zone list #
Action Specifier
Partition(s)
Partition(s)
Access Group
Action
Access Point Grant
Access Point Grant with
Override
Access Point Protect
Access Point Bypass
Access Point Lock
Access Point Exit
Access Point Group Grant
Access Point Group Grant
with Override
Access Point Group Protect
Access Point Group Bypass
Access Point Group Lock
Access Point Group Exit
Access Point Partition Grant
Access Point Partition Grant
with Override
Access Point Protect by
Partition
Access Point Bypass by
Partition
Access Point Lock by
Partition
Access Point Exit by Partition
Access Point Trigger On
Access Point Trigger Off
Access Point Group Enable
Access Point Group Disable
Enter the desired activation time (when the
action is to take place). Select from:
Description
Time
01
Beginning of time period.
02
End of time period.
03
During time period only (on at beginning of
time period, off at end).
For example, if bypass is selected to activate
during the time period, zones in a zone list
are bypassed at the beginning of the time
period and unbypassed at the end of the time
period.
04
Beginning and end of time period (e.g., a
coffee break buzzer). In this example, if relay
pulse is selected, the relay pulses for 2
seconds at the beginning of the time period,
signaling the beginning of the coffee break.
At the end of the time period it pulses again,
signaling the end of coffee break.
Action Specifier
Access Point #
Access Point #
Access Point #
Access Point #
Access Point #
Access Point #
Group #
Group #
Group #
Group #
Group #
Group #
Partition #
Partition #
Partition #
Partition #
Partition #
Partition #
Trigger #
Trigger #
Group #
Group #

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents