Honeywell ADEMCO VISTA-120 Installation And Setup Manual page 68

Partitioned security system with scheduling
Hide thumbs Also See for ADEMCO VISTA-120:
Table of Contents

Advertisement

VISTA-120 Installation and Setup Guide
Summer Time Start/End Month
2*01
0 = disable
1 = enable
Summer Time Start/End Weekend
2*02
0 = disable
1 = enable
Auto-Arm Delay (partition-specific)
2*05
00 = no delay
01-14 times 4 minutes (04-56) delay
15 = no auto arming
Auto-Arm Warning Period (partition-
2*06
specific)
01-15 times 1-minute warning
00 = no warning period
Auto-Disarm Delay (partition-
2*07
specific)
00 = no delay
01-14 times 4 minutes (04-56) delay
15 = no auto disarming
Enable Force Arm for Auto-Arm
2*08
(partition-specific)
0 = disable
1 = enable
Open/Close Reports by Exception
2*09
(partition-specific)
0 = disable
1 = enable
Allow Disarming Only During
2*10
Arm/Disarm Windows (partition-
specific)
0 = disable
1 = enable
Allow Disarm Outside Window if
2*11
Alarm Occurs
0 = disable
1 = enable
Enable GOTO for this Partition
2*18
(partition-specific)
0 = disable
1 = enable
Use Partition Descriptors
2*19
0 = disable
1 = enable
FIELD
TITLE and DATA ENTRIES
5-14
Enter the months (00-12) in which summer time starts and ends.
Enter 00, 00 if summer time does not apply to the user's region. Standard
setting for North America is 04,10.
NOTE: Summer time starts and ends at 2AM on the designated month and
weekend
Enter the start and end weekends for summer time as follows: 1=first;
2=second; 3=third; 4=fourth; 5=last; 6=next to last; 7=third from last.
Standard setting for North America is 1,5.
This is the time between the end of the arming period and the start of auto-
arm warning time (field 2*06).
This is the time that the user is warned by a keypad sounding and display to
exit the premises prior to auto arming of the system.
This is the time between the end of the disarming time period and the start of
auto disarming of the system.
If enabled, the system automatically bypasses any faulted zones when it
attempts to auto-arm.
If disabled, the system will not auto-arm.
If enabled, Open/Close reports are sent only if the openings/closings occur
outside the arm and disarm time periods.
NOTES:
Open reports are also suppressed during the closing time period in order to
prevent false alarms if the user arms the system, then re-enters the premises,
for example to retrieve a forgotten item.
Openings and closings are still recorded in the event log.
This field must be set to 1 if No Opening and No Closing reports are to be
sent.
If enabled, disarming of the system is allowed only during the
arming/disarming time periods, or if the system is in alarm (if 2*11 is set to 1).
NOTE: This applies only to Operator-level users. Installer, Master, and
Manager-level users can disarm the system at any time.
If enabled, allows the system to be disarmed outside the programmed disarm
(opening) time period if an alarm has occurred. Otherwise disarming is
allowed only during the disarm time period.
NOTE: Used only if field 2*10 is enabled.
If enabled, this partition can be accessed from another partition's keypad
using the GOTO command.
If enabled, the normal keypad display will include a partition number and four-
digit descriptor.
EXPLANATION

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents