Honeywell ADEMCO VISTA-120 Installation And Setup Manual page 66

Partitioned security system with scheduling
Hide thumbs Also See for ADEMCO VISTA-120:
Table of Contents

Advertisement

VISTA-120 Installation and Setup Guide
Chime on External Siren (partition-
1*47
specific)
0 = disable
1 = enable
Wireless Keypad Assignment
1*48
0 = none
1-8 = partition number
Suppress Transmitter Supervision
1*49
Sound
0 = disable
1 = enable
Number of Seconds Added per Day
1*50
Enter 00-30
Number of Seconds Subtracted per
1*51
Day
Enter 00-30
Send Cancel If Alarm + Off (partition-
1*52
specific)
0 = disable
1 = enable
Disable Download Callback
1*53
0 = callback required
1 = no callback required
Internal Clock Sync
1*54
0 = use AC sync for clock
1 = use internal crystal for clock
International Date Format
1*55
0 = disable (mm/dd/yy)
1 = enable (dd/mm/yy)
AC 60Hz or 50Hz
1*56
0 = 60Hz
1 = 50Hz
Enable 5800 RF Button Global Arm
1*57
0 = disable
1 = enable
Enable 5800 RF Button Force Arm
1*58
0 = disable
1 = enable
Suppress Status LED Output When
1*59
Zone 7 Keyswitch Enabled/Retain
Voltage Trigger Outputs
0 = disable
1 = enable
FIELD
TITLE and DATA ENTRIES
5-12
If enabled, the system produces chime annunciation on the external alarm
sounder.
Select the partition in which 5827/5827BD RF keypad is used.
If enabled, no trouble soundings occur on the keypad for transmitter check-in
failures.
Enter the number of seconds that will be added per day to correct the real-
time clock, if internal crystal synch is selected in 1*54.
Enter the number of seconds that will be subtracted per day to correct the
real-time clock, if internal crystal synch is selected in 1*54.
If enabled, Cancel reports are sent when the system is disarmed after an
alarm, regardless of how much time has gone by.
If disabled, Cancel reports are sent within Alarm Sounder Timeout period only.
Select whether a callback from the control panel is required for downloading.
Select the sync method for the real-time clock.
Select the date format for display in the event log.
Select the frequency for the AC mains.
If enabled, the system arms/disarms in accordance with the button's user's
global arming settings.
If enabled, allows the RF button user to force a bypass of all faulted zones
when arming the system.
NOTE: When attempting to arm the system, the keypad beeps once after the
button is pressed if any faulted zones are present. The user should then
press the button again within 4 seconds to force-bypass those zones and arm
the system.
If enabled, the system suppresses the keyswitch status LEDs and provides
voltage triggers on the J7 outputs.
EXPLANATION

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents