Honeywell CNI4 Operating And Installation Manual page 69

Table of Contents

Advertisement

9 Appendix
Item
Item Name
#
address)
3055
Device Wakeup time
3057
MasterLink session
timeout
3058
Last call / Known
Signal Strength
3059
Last Known Source
IP Address
3060
Last Known Source
Port
3062
Modem Firmware
Version
3063
Radio Modem
model
3064
Modem Manual
APN Enable
3065
RS-232 / RS-485
Serial Port Baud
Rate
3067
RS-232 Serial Port
Flow Control
3070
Include Baud in
CONNECT Message
3071
Modem Verizon
Enable
3072
Use Non-Verbose
(Numeric) Response
Codes
3073
Serial Port Delay
Before Sending
Packet
3075
RS-485 enable
Item Description
Modem sleep timeout after an AT command is
received. Example with 3055 set to 15s. If EC350
sends and ATDT command to Cloud Link, Cloud
Link will go back to sleep 15s later if no other
command is received.
MasterLink session timeout for both Cloud Link
4G Modem & EVC connection
RSSI - Received Signal Strength Indicator. Last call
known signal strength on a 2G network. Excellent :
-50dBm ð -70dBm Good : - 70dBm ð -85dBm Fair :
-85dBm ð -100dBm Poor : -100dBm ð -120dBm
Last call IP address
Last call IP Port
Typically select manual APN if a private static APN
is assigned to your SIM card.
Check in CNI2 manual
Select 'Enable' if operating on the Verizon network.
'Disable' if not. Changes to this parameter require
3016 (fetch parameters) to be set and Cloud Link
to be rebooted.
Check in CNI2 manual
During a Call-In sequence, the modem acquires the
data and will wait for a xx mSec gap before
sending the data to PowerSpring.
Defines the RS-232 or RS-485 operation of the
serial port. This setting has to match the Hardware
Switch.
Possible Values
16 bit integer Min =
1 Sec Max = 180
Sec
16 bit integer Min =
60 Sec Max = 960
Sec
Float (in dBm)
String
32 bit integer
String
String
0 - Disable, 1 -
Enable.
0 - 1200, 1 - 2400,
2 - 4800, 3 - 9600,
4 - 19200, 5 -
38400, 6 - 57600, 7
- 115200.
0 - Disable, 1 -
Enable.
0 - Disable, 1 -
Enable.
0 - Disable, 1 -
Enable.
0 - Disable, 1 -
Enable.
16 bit integer Min =
10 mSec Max =
10000 mSec
0 - Disable, 1 -
Enable.
Honeywell
| 65

Advertisement

Table of Contents
loading

Table of Contents